Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.
Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.
The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.
Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.
Adopting a two-box mobile structure, the high temperature zone reaches 150 ° C and the low temperature zone reaches -40 ° C, the conversion time is within 10 seconds, and the recovery time is within 5 minutes. It is equipped with a touch screen controller and rigid polyurethane insulation material.
Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.
Adopt two-box mobile design, temperature recovery time ≤ 5 minutes, conversion time ≤ 10 seconds. With paperless recording function, real-time display of temperature Linear dispersion, support for a variety of test specifications, the use of environmentally friendly refrigerant and high-efficiency freezing system.
Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Impact conversion time is within 10 seconds, and the temperature recovery time is within 5 minutes, meeting the requirements of international testing standards such as MIL and IEC.
The three-box structure is used to achieve independent temperature control in the high temperature zone, low temperature zone and test zone, with a temperature conversion time of less than or equal to 10 seconds. It is equipped with rigid polyurethane foam insulation materials and supports 2 or 3 boxes of Impact mode to meet different standard testing requirements.
Dynamic Impact is achieved with a two-box mobile structure, with a hot and cold conversion time of 10 seconds and a temperature recovery time of 5 minutes. It is equipped with rigid polyurethane foam insulation material, with ultra-low temperature thermal conductivity and multiple safety protection devices.
Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.
The three-box structure is used to achieve a completely static test zone, with a temperature conversion time of ≤ 10 seconds and a temperature recovery of ≤ 5 minutes. It has an Impact range of 150 ° C in the high temperature zone and -55 ° C in the low temperature zone, meeting the needs of rapid temperature change testing.
The three-box structure is used to realize the static test sample, the strong cooling hot air circuit switching technology, the temperature conversion time is less than or equal to 10 seconds, the temperature recovery time is less than or equal to 5 minutes, and the temperature control function is independent in the high temperature zone, the low temperature zone and the test zone.
Dynamic impact testing is achieved with a two-box mobile structure. The impact conversion time is within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with rigid polyurethane foam insulation materials to ensure low thermal conductivity and meet a number of national standards.
The three-box heat storage and cold storage structure is adopted to achieve rapid temperature conversion of ≤ 10s, and the temperature recovery time is ≤ 5 minutes. It supports Impact testing at 150 ° C in high temperature zone and -40 ° C in low temperature zone, and has program memory and Linear dispersion recording functions.