High and low temperature protection

High and low temperature protection monitors the equipment's operating environment through temperature sensors. When the temperature exceeds the set range, it automatically cuts off the power supply or activates cooling/heating devices to prevent changes in material properties or equipment damage. It is applied in detection processes that require stable temperature conditions, such as constant temperature chambers and aging test machines.
Selection
When selecting, ensure the device's operating temperature range matches the detection requirements, check the protection response speed and accuracy, consider the sensor type and installation method, examine the alarm mode and reset mechanism, evaluate power compatibility and protection rating, and confirm maintenance needs and environmental adaptability.

Terms

Standards

Instruments

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

8L Tank with -10~ 100 ℃ wide Temperature range, equipped with maintenance-free pressure pump to achieve two-way mixing, support single point and two point temperature calibrating, with low level protection and high temperature protection function.

$ 1122.00

Temperature range -5~ 160 ℃ and Temperature Uniformity up to +/- 0.05 ℃, using non-heat centrifugal circulation pump and U-shaped return design, to ensure that the temperature field of the Tank is highly uniform, equipped with multiple safety protection devices to improve the reliability of use.

$ 1790.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.

$ 1927.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.

$ 14703.00

Adopting a specific air inlet and outlet device, inert gas can be intRoduced to achieve high temperature protection, with a maximum temperature of 1200 ° C, a studio volume of 30L, and a shell made of cold plate and section steel and sprayed at high temperature.

$ 1183.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple protection functions.

$ 11564.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, U-shaped return design to achieve turbulence and high uniformity, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with low water level protection and Compressor multiple safety functions.

$ 6275.00

Temperature control accuracy of +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to reduce the impact of temperature field, U-shaped reflux design to achieve a high degree of uniform temperature field, with multiple safety protection devices.

$ 1610.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple protection to ensure stable and safe operation.

$ 1327.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1703.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with programmable Touchscreen controller, supports multi-stage program control and real-time data monitoring to ensure stable and reliable testing process.

$ 6983.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1335.00

The centrifugal circulation pump without heat is adopted to reduce the influence of temperature field, and the U-type reflux circulation realizes Temperature Uniformity +/- 0.05 ℃. It has safety devices such as power-off protection and low water level alarm, and can choose multi-stage temperature control program.

$ 1222.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Corrugated Board Impact Resistance - Application of Puncture Strength Tester in Packaging Testing
The impact resistance of corrugated cardboard is crucial for transportation protection, with puncture strength being a key indicator of its ability to withstand dynamic impacts. The puncture strength tester simulates impacts using a pendulum system and measures the energy consumed to penetrate the cardboard, with results expressed in joules or kilojoules per square meter.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.