Online RheoMeter

Online rheometers directly reflect changes in viscosity by measuring the relationship between shear stress and shear rate of materials in real time during pipeline flow. They are used to monitor the fluid state of coatings, inks, and other substances on production lines, ensuring process stability and product consistency.

Instruments

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

Micro vibration technology implementation of real-time online measurement, range coverage of 0-5~ 50-5000pa.s, accuracy of +/- 0.5%, temperature 500 ℃ and Response Time only 2 seconds, suitable for high temperature and high voltage conditions.

$ 7335.00

The laser light scattering principle to achieve rapid measurement, detection sensitivity of 0.001mg/m ³, with online automatic mechanical Adjustment, built-in optical path self-cleaning system to avoid contamination of core components, support a variety of cutter selection.

$ 5399.00

Fast measurement using laser light scattering principle, with online automatic mechanical Adjustment, Measurement range 0.01-100 mg/m ³, built-in optical path self-cleaning system to avoid pollution, support a variety of cutters and sampling modes.

$ 5399.00

Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.

$ 3244.00

The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.

$ 683.00

Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.

$ 11125.00

The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.

$ 683.00

The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.

$ 683.00

The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.

$ 683.00

The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.

$ 683.00

The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.

$ 683.00

Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.

$ 683.00

Articles

Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Melt Flow Indexer and Torque Rheometer in the Evaluation of Processing Properties of Thermoplastic Resins
This article introduces the differences and selection methods between melt indexers and torque rheometers in evaluating the processing properties of thermoplastic resins.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Capillary Rheometer for Determining the Shear Viscosity Curve of Hot Melt Adhesives
This article introduces the method of measuring the shear viscosity curve of hot melt adhesives using a capillary rheometer. The principle involves pushing molten hot melt adhesive through a capillary, measuring the pressure and flow rate, and then calculating the shear stress and viscosity.
Can you distinguish between a rotational viscometer, a rheometer, and a cone-plate viscometer?
Rotational viscometers, rheometers, and cone-plate viscometers are core instruments in the field of material characterization, with significant differences in measurement principles, geometric structures, and functional positioning.