Quantitative Coating Rod

The quantitative coating rod controls the transfer amount of coating through precise grooves on its surface, forming a wet film of uniform thickness on the substrate. It is used in laboratories to simulate the blade coating process and evaluate the leveling, hiding power, and other properties of coatings. It is suitable for quality control and formulation development in fields such as ink printing and paper coating.
Selection
Select the groove depth based on the viscosity of the sample to be tested, with common specifications ranging from 10 to 200 μm; match the coating rod length according to the substrate width; metal materials are suitable for corrosive samples, while stainless steel offers durability and corrosion resistance; during verification, perform parallel tests with rods of different specifications to observe coating uniformity and consistency with the expected thickness.

Terms

Standards

Instruments

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Wet film thickness 22.9 microns, diaMeter 9.52 mm, the forming Rod uses an extrusion process to process continuous grooves, with no wire breakage and easy cleaning; the wire-wound Rod is based on the traditional principle, and there are differences in coating amount.

$ 167.00

Using the formed pRoduction process, the wet film thickness is 6 microns, the accuracy is 0.5 microns, the cleaning is convenient and there is no worry of broken wire, to ensure the precision and durability of the coating prepative.

$ 120.00

Support bar and Drawdown blade double coating method, suitable for high, medium and low viscosity materials; coating speed 1~ 300mm/s stepless adjustable, Blade Coating accuracy +/- 3μm; equipped with innovative clamshell magnetic Drawdown blade and simple bar installation, easy to clean and load; Heating and Vacuum chuck function to improve Spreader mass.

$ 10562.00

Wet film thickness 45μm, main Rod diaMeter 10mm, effective application width 600mm, using SUS304 material, Coating Weight, length and surface preparation can be customized, suitable for a variety of Spreader conditions.

$ 267.00

Support bar and Drawdown blade two coating methods, suitable for different viscosity materials. Equipped with heating and Vacuum chuck function, servo motor to ensure stable operation. Drawdown blade film thickness control accuracy is high, uniform film.

$ 6205.00

The sampling area is 100mm ² and the error is controlled within +/- 0.35cm ², which can handle 0.1~ 1.2mm Film thickness materials. The circular sampling design is used to ensure the standard of the sample, and the operation is simple and the results are reliable.

$ 417.00

Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.

$ 178.00

Using SUS304 stainless steel material, wet film thickness 52μm, main Rod diaMeter 10mm, effective application width 600mm, groove design can achieve accurate Coating Weight control.

$ 267.00

Utilizing a dual coating method with wire rod and doctor blade, the coating speed is adjustable from 1 to 300 mm/s with stepless speed control, ensuring high precision in film thickness control. Equipped with vacuum adsorption and heating functions, the temperature uniformity reaches ±1°C. The flip-top design facilitates easy cleaning.

$ 24279.00

The wire-wound structure enables coating with a 171.5-micron thick film, while the stainless steel material ensures corrosion resistance and long-term durability. The 9.52mm diaMeter Rod body, combined with 1.91mm steel wire, ensures operational stability.

$ 167.00

Imported High Accuracy coating Rod, Spreader thickness range 1~ 571.5μm, accuracy +/- 0.003mm, speed 5~ 200mm/s, support Touchscreen control and a variety of customized functions.

$ 6367.00

The extrusion production process ensures uniform coating, with a wet film thickness of 60μm meeting the demands of precise experiments. The 304 stainless steel material is durable and easy to clean, making it suitable for diverse coating performance tests.

$ 178.00

With bar and Drawdown blade two Spreader mode, using clamshell Drawdown blade head and new bar Installation method, easy to clean. Spreader speed and length can be freely adjusted, film thickness control accuracy is high, suitable for Glass, cardboard and other substrates.

$ 2978.00

Formed design Coating Weight is about twice the wide-wound drawdown bar, wet film thickness 13μm, film accuracy of 0.5 micron, 304 stainless steel material to ensure durability.

$ 157.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Differential Scanning Calorimetry for Measuring the Degree of Cure of Polymer Optical Waveguide Materials
This article introduces a method for determining the degree of curing in polymer optical waveguide materials using a differential scanning calorimeter. The degree of curing is a key indicator affecting material performance, and this instrument quantitatively analyzes it by measuring the thermal effects during the curing reaction.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Pull-off adhesion tester quantitatively measures bond strength.
The pull-off adhesion tester measures the bonding strength between coatings, linings, and substrates by applying a vertical tensile force.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.