Internal heating technology shortens the heating time by 50%, the vacuum environment can be reduced to 133Pa, the aluminum shelf conducts heat quickly and reduces heat loss, double-decked Glass doors are easy to observe, and support inert gas protection to prevent oxidation.
Internal heating design shortens heating time by 50%, vacuum environment can quickly dry heat sensitive substances and avoid oxidation, Studio Temperature Fluctuation +/- 1 ℃, equipped with tempered Glass door for easy observation.
The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.
The digital vacuum Gauge is used to automatically control the Vacuum Level, with an accuracy of +/- 1%; the heating element is located in the Shelf of the box to shorten the heating time by 50%; the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, effectively improving the drying efficiency.
Double-decked independent heating and vacuuming do not interfere with each other, Vacuum Level up to 133Pa, rectangular vacuum Chamber improves space utilization, resilience silicone rubber door seal ensures high vacuum, over-temperature protection improves safety.
The digital pressure sensor is used to automatically control the Vacuum Level with accuracy +/- 1%; the programmed vacuum cycle can shorten the drying time by more than 50%; 7 groups of 63-step programmable temperature control support slope mode to achieve accurate heating and cooling rate control.
Double-decked independent heating and vacuuming do not interfere with each other, rectangular vacuum Chamber improves space utilization, resilience silicone rubber door seal ensures high Vacuum Level, Temperature range RT + 10~ 200 ℃ and temperature fluctuation +/- 1 ℃.
The effective volume utilization rate of rectangular vacuum Chamber is high, each layer can be independently heated and vacuumed to inject nitrogen without interfering with each other, the temperature control accuracy is +/- 1 ℃, the Vacuum Level is 133Pa, and the double-decked tempered Glass door is easy to observe.
Double-decked independent heating and vacuuming design, Vacuum Level up to 133Pa, temperature fluctuation +/- 1 ℃, stainless steel studio and tempered Glass door, support programmed control stoving process.
Shelf heating design in the box reduces heating time by 50%, aluminum shelf conducts heat quickly and does not oxidize at high temperature, Vacuum Level control accuracy of +/- 1%, can prevent sample oxidation in vacuum or inert gas environment.
Rectangle vacuum Chamber improves space utilization, double-decked tempered Glass door for easy observation, over-temperature protection temperature control port enhances safety, Vacuum Level up to 133Pa, Temperature Fluctuation +/- 1 ℃, programmable control heating and vacuum holding time.
With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.
Vacuum environment reduces the boiling point of liquid, suitable for heat-sensitive substances; stainless steel liner is easy to clean, vacuum degree of 133Pa; microcomputer PID control, with over-temperature alarm function, four directions heating temperature uniformity.
Vacuum environment reduces the boiling point of the liquid, suitable for drying heat-sensitive substances and powder samples to avoid sample movement. Temperature range RT + 50~ 200 ℃, vacuum degree < 133Pa, liner made of stainless steel to ensure clean and uniform heating.
The rectangular vacuum Chamber improves space utilization, the stainless steel studio is easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures stoving conformity.