With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.
Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.
Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.
With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.
Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.
Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.0050 ° C, and multiple safety functions such as low water level protection and temperature runaway alarm.
With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes a high degree of uniformity in the temperature field, with a temperature control accuracy of +/- 0.0050 ° C. It has multiple safety functions of low water level protection and Compressor.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and temperature runaway alarm function to ensure the safety and stability of the experiment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes turbulence and high uniformity, Temperature Uniformity +/- 0.0050 ℃, with multiple safety functions such as low water level protection and temperature loss protection.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, U-shaped return design to achieve turbulence and high uniformity, Temperature Uniformity +/- 0.0050 ℃, resolution 0.0001 ℃, with low water level protection and Compressor multiple safety functions.