Using a 29.7 × 29mm pump and a 2 kg load weight, the material consistency was accurately determined by the spread diffusion diaMeter of the Basis Weight specimen on the Glass platen, meeting the standard test requirements.
The device uses 20.70ml pump volume and 2kg weight load, which can accurately measure the flow spread diffusion diaMeter of the sample under fixed pressure, ensuring the consistency test, repeability and accuracy.
Nozzle of stainless steel with anodic oxidation aluminum Cup body, diaMeter of flow hole 6mm, viscosity measurement range of 22-2000cSt, suitable for rapid consistency determination of Newtonian behavior liquid.
Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.
High subdivision drive stepper motor ensures accurate and stable Rotation speed, Measurement accuracy of +/- 1% F. S, viscosity range of 1~ 1000000mPa · s, LCD display viscosity, Rotation speed and other Multi-ParaMeter, timing function to ensure thixotropic liquid data conformity.
Measurement accuracy of +/- 2% F.S, repRoducibility +/- 0.5% F.S, viscosity range covering 1~ 600000mPa · s, with screen direct display viscosity, speed, torque and alarm function.
With 18 speed Rotation speed control and 0.3-100 rpm range, automatic calculation range, support user-defined calibrate, Repeatability up to +/- 0.2% F. S, accuracy +/- 1% F. S, can measure 1~ 2000000mPa · s viscosity.
Using 998 stepless speed regulation and automatic scanning functions, Measurement accuracy of +/- 1% F.S., Support real-time viscosity Linear dispersion display and 30 data storage to meet a variety of viscosity measurement needs.
Equipped with four rotors, viscosity measurement range 20~ 100000mPa · s, fixed Rotation speed 6/12/30/60rpm, can display viscosity, Rotation speed, torque and maximum viscosity value, repRoducibility +/- 1% F.S.
Rotation speed is continuously adjustable by microcomputer controlled stepper motor, viscosity range is 10~ 6000000 mPa.s, Measurement accuracy +/- 3% F.S., compact structure and good anti-interference performance.
Dial display, viscosity measurement range of 10~ 100000mPa · s, accuracy +/- 5% F. S, equipped with four rotors and four Rotation speed, suitable for a variety of fluid viscosity detection, easy to operate.
Viscosity measurement range 1~ 2000000mPa · s, repRoducibility +/- 0.5% F. S, sample volume only 25~ 30mL, Rotation speed control to meet different viscosity measurement needs.
With 200-320000000mPa · s wide range and +/- 1% Measurement accuracy, support PT100 temperature detection and 10 sets of program storage functions, can automatically calculate Rotor speed combined range.
Adopt 16-bit microcomputer processor and stepper motor high subdivision drive to ensure smooth and accurate speed. Measurement accuracy of +/- 1% F. S, viscosity range covering 1 to 2000000mPa · s, the screen directly displays viscosity, speed, torque and rotor information, easy to operate.
Measurement accuracy of +/- 1% F. S, repRoducibility of +/- 0.5% F. S, support continuously variable speed control Rotation speed 1~ 60rpm, real-time display of rotor measurable maximum viscosity value, easy to operate.