Visual Color Comparator

The visual colorimeter directly compares the color difference between a sample and a standard color card using the human eye, utilizing a standardized lighting environment to minimize visual errors. It is used for color quality control in products such as paints and plastics, enabling quick determination of whether the product color meets the required standards.

Instruments

Equipped with 18 standard color level solutions, in line with GB/T1722 standards, using visual ratio method, suitable for Color Determination, Test Ambient Temperature 23 +/- 2 ℃, to ensure accurate and reliable results.

$ 151.00

Visual aiming and manual measurement, measurement range up to +/- 180 °, equipped with LED Illuminant to extend the service life, support 100mm/200mm ordinary testtube.

$ 444.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

With visual and automatic dual measurement mode, to meet the needs of deep Color sample detection. Temperature resolution 0.1 ℃, can process three samples at the same time, support 0.1-10 ℃/min continuous adjustable heating rate.

$ 3533.00

Provide 25, 40, 70, 100 four profile specifications, size 87x87x2.5mm, weight only 60 grams, Portable design is convenient for quick comparison and evaluation on site.

$ 505.00

The phase transition process of samples can be detected by visual method, and three samples can be processed simultaneously and the average value can be calculated. Temperature range RT +~ 280 ℃, resolution 0.1 ℃, support 0.5-3 ℃/min four-speed heating rate, suitable for dark sample determination.

$ 1106.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

Adopt internationally recognized LOVIBOND color scale, measurement range red 0.1-79, yellow 0.1-79, blue 0.1-49 LOVIBOND units, minimum indication 0.1, equipped with three specifications Cuvette to meet multi-sample testing needs.

$ 677.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Dual independent light sources can simulate D65 and D50 environments, with a color rendering index of up to 98, all-metal construction ensures durability, and the operating table is designed with a beveled surface to meet visual observation habits.

$ 1848.00

Standard light sources, color rendering index up to 98, all-metal structure to ensure durability, large folio size easy to operate, with light source Timer function, inclined design in line with visual observation habits.

$ 1461.00

In line with ISO3664 standards, the color rendering index reaches CRI = 98, dual Illuminant configuration with Timer, all-metal structure is stable and durable, the inclined table design conforms to visual observation habits, and the light is uniform.

$ 1332.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

With explosion-proof IP66 Protection Rating, support 4G remote control and paraMeter configuration. The visual distance of the high definition color screen is 10 Meters, the Response Time T90 ≤ the national standard, the detection accuracy ≤ +/- 3% FS, suitable for a variety of installation methods.

$ 693.00

Articles

The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Standardized ink color evaluation environment for visual color comparison cabinets
This article introduces the standardized application of visual color comparison boxes in ink color evaluation. It emphasizes that to ensure the accuracy and consistency of color judgments, the evaluation environment must be strictly controlled.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Comparative Study of Lovibond Colorimeter and Iron-Cobalt Colorimeter
The Lovibond colorimeter and the iron-cobalt colorimeter are two widely used visual color measurement instruments in the industrial field. Both are designed based on the principle of standard color comparison, yet they exhibit significant differences in their specific implementation methods and application standards.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.