Visible UV spectroPhotoMeter

A UV-Vis spectrophotometer utilizes the absorption characteristics of substances at specific wavelengths of light to analyze component concentrations by measuring the sample's absorbance. In the coatings and inks industry, it is used to detect dye purity and color fastness, while in plastics and paper manufacturing, it monitors additive content. The light source emits ultraviolet and visible light, the monochromator separates the wavelengths, and the detector receives the transmitted light and converts it into an electrical signal.
Selection
When selecting, consider that the measurement wavelength range covers 190–1100 nm, and the bandwidth matches the sample resolution requirements. Pay attention to baseline stability and stray light indicators to ensure accurate low-concentration detection. The sample chamber size should accommodate cuvette specifications, and the automatic sampling function improves batch detection efficiency. The software must support industry-standard detection methods, while maintenance costs include lamp life and calibration cycles.

Terms

Standards

Instruments

1200L/mm UV dedicated grating and proportional double beam of light design, stray light ≤ 0.03% T, equipped with 10cm sample holder and automatic octet cell, support wavelength scanning and a variety of test modes.

$ 3623.00

Adopt 1200L/mm UV special grating and imported photoelectric converter, stray light ≤ 0.03% T, Wavelength range 190~ 1100nm, with automatic correction wavelength error function, support 10cm sample holder to meet special needs.

$ 2252.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 1.8nm, can store 100 standard Linear dispersion and 200 data, support a variety of Cuvette and direct printouts.

$ 1300.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

Using Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can store 100 standard Linear dispersion and 200 data, supports a variety of Cuvette and direct printouts.

$ 1300.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional dual beam of light design supports automatic octet cell, Wavelength range 190~ 1100nm, with professional wavelength correction function.

$ 2978.00

Automatic correction of ABS value with one button, Light spectrum Bandwidth 4nm, Wavelength range 195-1000nm, 5-100mm Cuvette can be placed, Support Transmittance, Absorbance, concentration factor and other Operating Modes.

$ 816.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octagonal cell sample holder to improve test efficiency, Wavelength range 190~ 1100nm coverage of a wide range of applications.

$ 3268.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

One key automatic correction ABS value, Wavelength range 190~ 960nm, can be placed 5~ 100mm Cuvette, equipped with RS232 data output interface, support Transmittance, Absorbance, concentration factor and concentration direct reading Operating Mode.

$ 1058.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

Using Czerny-Turner light path to ensure detection of linear Precision, stray light ≤ 0.05% T, can store 100 standard Linear dispersion and 200 data, support a variety of test modes such as DNA/protein testing and kinetic testing.

$ 1397.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

Articles

UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.