Doctor Blade Coating Tester Coater

The blade coating tester uses a motor to drive the blade to move evenly across the substrate surface, spreading the coating into a film at a set thickness. It is used to simulate the coating process and test the leveling, hiding power, and coating uniformity of coatings. It is suitable for laboratory prototyping and quality control of materials such as paper and films.

Instruments

Using Metering Rod & doctor blade double Spreader mode, Spreader accuracy up to +/- 0.001mm, Spreader rate 5~ 200mm/s adjustable, fixed substrate by vacuum adsorption to ensure film uniformity and repRoducibility.

$ 2736.00

Spreader speed 5~ 180mm/s, Spreader area 400 * 300mm, using Metering Rod & doctor blade and vacuum adsorption system to ensure Spreader uniformity and Stability, can be customized automatic inking function.

$ 9755.00

Using Metering Rod & doctor blade dual Spreader method, Spreader accuracy is up to +/- 10μm, Film thickness range is 0-5000μm. Spreader rate and stroke are controlled by vacuum adsorption to fix the substrate, and the touch screen can effectively improve film repRoducibility and conformity.

$ 3462.00

Adopt bar and drawdown blade composite coating method, bar accuracy +/- 0.005mm, drawdown blade thickness range 0.1-10 mm, Vacuum Area 1280 * 960mm, coating speed 1~ 300mm/s stepless speed regulation, suitable for wide voltage input.

$ 19438.00

Utilizing a dual coating method with wire rod and doctor blade, the coating speed is adjustable from 1 to 300 mm/s with stepless speed control, ensuring high precision in film thickness control. Equipped with vacuum adsorption and heating functions, the temperature uniformity reaches ±1°C. The flip-top design facilitates easy cleaning.

$ 24279.00

With bar and drawdown blade two coating methods, coating speed 1~ 300mm/s stepless speed regulation, clamshell drawdown blade design for easy cleaning, bar accuracy of +/- 0.001mm, Blade Coating thickness range of 0.1~ 10mm, effective coating area 1500 * 300mm.

$ 7335.00

Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm, equipped with automatic feeding system and vacuum adsorption, to achieve stable Spreader and efficient operation.

$ 8949.00

Using Blade Coating method, Spreader accuracy of +/- 10μm, Spreader thickness range of 0~ 5000μm, support stepless speed control and Touchscreen operation, effectively improve film conformity and experimental efficiency.

$ 1606.00

Adopt bar and drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, Blade Coating Film thickness 0.1~ 10mm, equipped with Vacuum chuck and heating function, film uniform accuracy is high.

$ 14597.00

Adopt bar and Drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, bar accuracy +/- 0.001mm, equipped with clamshell Drawdown blade head for easy cleaning, Glass countertop heat resistance 600 ℃.

$ 5560.00

The application width can be adjusted freely, and the drawdown blade Coater can be adapted to meet different experimental testing needs and realize flexible film operation.

$ 154.00

Adopt imported accessories to ensure Stability, Blade Coating accuracy up to +/- 0.003mm, coating speed 5~ 200mm/s adjustable, effective coating area 400 * 400mm, improve film repRoducibility by controlling speed and pressure.

$ 2655.00

Using meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, clamshell Drawdown blade is easy to clean, supports 1-300mm/s stepless speed regulation, Glass countertop heat resistance 600 ℃ and scratch resistance.

$ 9433.00

Adopt bar and Drawdown blade double coating method, coating speed 5~ 180mm/s adjustable, Spreader thickness range 0~ 10mm, equipped with clamshell Drawdown blade head and Touchscreen control, easy to operate and easy to clean.

$ 9755.00

With bar and Drawdown blade two coating methods, coating speed 1-300mm/s stepless speed regulation, Blade Coating thickness 0.1-10 mm, using clamshell design for easy cleaning, equipped with High Accuracy Film Applicator to ensure Spreader uniformity.

$ 5237.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
How to Coat High-Viscosity Slurry – Parameter Setting Tips for Blade Coaters
This article primarily discusses the parameter setting techniques for high-viscosity slurries on blade coaters. High-viscosity slurries exhibit characteristics such as shear thinning, so it is essential to leverage shear effects during coating to facilitate slurry spreading. After coating, the viscosity should recover quickly to prevent sagging.
What are some cost-effective alternatives to roll-to-roll coaters for the early stages of flexible film R&D when the investment is too high?
The investment in roll-to-roll coating machines is too high. What are some cost-effective alternatives for the early stages of flexible film research and development? Among blade coating, spin coating, and spray coating, which one would you choose?