Circulating Stirring Thermostatic Bath

The circulating stirred constant temperature bath uses a pump to drive liquid circulation and mechanical stirring to achieve uniform and stable temperature inside the bath. It is used for constant temperature treatment of laboratory samples, maintaining the set temperature during processes such as coating viscosity testing and ink curing.
Selection
Select the heating and cooling system based on the experimental temperature range and accuracy; determine the tank volume according to the container size; choose the inner tank material considering media compatibility; the stirring speed must meet the sample temperature uniformity requirements; pay attention to the configuration of safety protection features.

Terms

Standards

Instruments

Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming Tank body to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 1293.00

Temperature range -20~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system is used for rapid cooling, the overall foaming and heat insulation of the Tank body reduces the loss of cooling capacity, and circulating stirring ensures Temperature uniformity.

$ 1653.00

Imported Pt100 temperature sensor, Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 2575.00

Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.

$ 3155.00

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

Four-hole independent magnetic stirring can be stepless speed regulation and display Rotation speed, Temperature range 15~ 120 ℃, Temperature Fluctuation +/- 0.05 ℃, 4-sided Glass design is easy to observe sample changes.

$ 1492.00

Temperature range -80~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, double Compressor cascade refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity in the Tank.

$ 5673.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

4-Sided Glass design is easy to observe sample changes, four-hole independent temperature control accuracy +/- 0.05 ℃, magnetic stirring can be stepless speed regulation, accelerate liquid temperature transfer, achieve rapid uniform heating.

$ 1944.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Temperature range -65~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity in the Tank.

$ 4801.00

Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and magnetic stirring system to enhance experimental flexibility.

$ 1093.00

The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1653.00

Adopt microcomputer PID temperature control, temperature control accuracy +/- 0.5 ℃, ensure temperature stability. Magnetic stirring output torque, keep Rotation speed constant, over-temperature sound and light alarm to protect sample safety.

$ 1016.00

Adopt non-heat centrifugal circulating pump to avoid self-heating affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control or magnetic stirring function to enhance application flexibility.

$ 1079.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.