Camellia Oil ColoriMeter

The tea oil colorimeter captures the visible light wavelengths reflected by the tea oil sample through an optical sensor and converts them into digital chromaticity values. It is used to detect the color grade of tea oil and monitor processing quality and storage stability in the edible oil production process.
Selection
When selecting, pay attention to the measurement accuracy to ensure it meets industry standards, and the instrument should have temperature compensation functionality. Consider the oil resistance of the sample cell material, and ensure the operation interface is user-friendly. Verify the validity of the calibration certificate and ensure convenient after-sales maintenance.

Terms

Instruments

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

As an Optional accessory of air Compressor, it can effectively separate oil and water, improve compressed air mass, and is suitable for industrial environments that require gas purity.

$ 154.00

Adopt oil pump forced oil inlet device, can operate continuously under 1.33 × 10 ³ Pa intake pressure, gas distribution ballast to prevent pump oil mixing, pumping speed 2L/S, Ultimate vacuum degree up to 0.006mbar, support a variety of interface conversion.

$ 375.00

Pure oil-free design, displacement 116L/min, exhaust pressure 8bar, automatic start and stop, low energy consumption, high gas cleanliness, simple operation and convenient maintenance.

$ 353.00

The pure oil-free design ensures that the gas has no oil molecules, the noise is as low as 59dB, the lame plating in the gas storage Tank is rust-proof, the service life is more than 15,000 hours, the exhaust pressure is adjustable from 5 to 8 Bar, and the automatic pressure switch controls start and stop.

$ 1201.00

Noise is as low as 54 decibels at work, displacement is 155 liters per minute, pure oil-free piston system ensures clean gas, Nano coating cylinder liner enhances durability, automatic start-stop saves energy and saves electricity.

$ 832.00

Using D/8 lighting system, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration technology to ensure measurement accuracy, lithium battery supports 12,000 consecutive tests.

$ 202.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

With oil-free lubrication piston system, noise is as low as 52 dB, exhaust volume is 118 L/min, automatic start and stop and multiple Safety protection, cylinder liner application Nano coating technology to extend service life.

$ 880.00

The pure oil-free design ensures that the gas is clean, the noise is as low as 42 decibels, the exhaust volume is 116L/min to meet a variety of needs, and the automated operation does not require special personnel to be on duty, making it safe and reliable.

$ 741.00

The pure oil-free design ensures that the gas is free of oil pollution. The Power 3000w provides strong power, with noise as low as 62dB. It is equipped with 4 pump heads to improve exhaust efficiency. The air pressure can be adjusted within the range of 5 to 8 Bar to meet different needs.

$ 2010.00

Noise as low as 52 dB, pure oil-free design ensures zero gas pollution, equipped with 60L buffer Tank and electronic start-stop controller, providing stable air pressure output, suitable for a variety of industrial environments.

$ 961.00

Noise is as low as 52 dB during operation, oil-free lubrication piston system and Nano coating cylinder liner are used, and the exhaust volume reaches 236L/min. Automatic start-stop design reduces energy consumption, and supports Filter selection to improve gas cleanliness.

$ 1526.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Double oil piston pump design, high voltage 63MPa, hollow double oil cylinder center aperture 65mm, with graded unloading function and peak holding, can store 50 data, convenient and reliable operation.

$ 1389.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.