Touchscreen Visible SpectroPhotoMeter

The touchscreen visible spectrophotometer controls the light source to illuminate the sample via a touchscreen, measuring the absorption intensity of visible light by substances. It is used for color difference analysis of coatings and inks, detection of plastic components, and quality control in the papermaking process.
Selection
When selecting, consider the touchscreen's response speed, compatibility of the sample chamber with plastic films or liquids, a wavelength range covering 400-700nm, industry-specific detection software, and ensure the instrument dimensions fit the laboratory workspace.

Terms

Standards

Instruments

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

Dual beam of light path structure with 1600L/mm holographic blazing grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with Touchscreen and dedicated Software support map data processing.

$ 5883.00

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.

$ 270.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 330~ 1000nm, High Linear and Stability, Support a variety of Measurement modes.

$ 364.00

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Using 1200L/mm grating and C-T monochromator structure, stray light ≤ 0.05% T, wavelength Precision +/- 1nm, support automatic wavelength correction and wide range measurement to ensure stable and reliable data.

$ 800.00

Adopt double beam of light path structure with 1600L/mm blazing grating, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support map four arithmetic and data export function, with automatic wavelength calibrating mechanism.

$ 5399.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

Adopt dual beam of light path structure and 1600L/mm holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support a variety of data processing and comparison analysis functions.

$ 5883.00

Adopt Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can accommodate 5~ 100mm Cuvette, support a variety of Basis Weight test methods.

$ 1009.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 325~ 1000nm, to ensure High Accuracy Testing and Stability, wide sample Chamber supports 100mm sample holder.

$ 356.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 4.0nm, can accommodate 5~ 100mm Cuvette, support automatic wavelength calibration and Data storage.

$ 858.00

Using 1200L/mm high-performance grating and imported photoelectric converter, stray light is as low as 0.03% T, wavelength Precision +/- 0.5nm, wide sample Chamber can expand 10cm sample holder, support automatic wavelength correction and Illuminant switching.

$ 1848.00

Articles