1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.
1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.
Dual beam of light path structure with 1600L/mm holographic blazing grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with Touchscreen and dedicated Software support map data processing.
Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.
Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 330~ 1000nm, High Linear and Stability, Support a variety of Measurement modes.
Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.
Using 1200L/mm grating and C-T monochromator structure, stray light ≤ 0.05% T, wavelength Precision +/- 1nm, support automatic wavelength correction and wide range measurement to ensure stable and reliable data.
Adopt double beam of light path structure with 1600L/mm blazing grating, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support map four arithmetic and data export function, with automatic wavelength calibrating mechanism.
1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.
Adopt dual beam of light path structure and 1600L/mm holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, equipped with color Touchscreen and special software, support a variety of data processing and comparison analysis functions.
Adopt Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can accommodate 5~ 100mm Cuvette, support a variety of Basis Weight test methods.
Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 325~ 1000nm, to ensure High Accuracy Testing and Stability, wide sample Chamber supports 100mm sample holder.
Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.
Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 4.0nm, can accommodate 5~ 100mm Cuvette, support automatic wavelength calibration and Data storage.
Using 1200L/mm high-performance grating and imported photoelectric converter, stray light is as low as 0.03% T, wavelength Precision +/- 0.5nm, wide sample Chamber can expand 10cm sample holder, support automatic wavelength correction and Illuminant switching.