Static High and Low Temperature Test Chamber

Static high-low temperature test chambers control the internal temperature through refrigeration and heating systems to simulate a product's endurance in a fixed temperature environment. They are used to detect the performance changes of materials under set high or low temperature conditions, commonly applied in verifying the temperature adaptability of electronic components and chemical materials.
Selection
When selecting, consider the temperature range to cover testing needs, the uniformity affecting result consistency, the heating and cooling rates matching testing standards, and the chamber size accommodating the sample volume. Pay attention to sensor accuracy and system stability, and confirm functional configurations based on common standards such as GB/T and IEC.

Terms

Standards

Instruments

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.

$ 9352.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.

$ 5560.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature cycle change test, suitable for aging test and material performance inspection.

$ 7109.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

Temperature control range -60~ 150 ° C, studio volume 80L, suitable for high temperature and low temperature cycle change testing, in line with a number of national standards, equipped with perfect protection devices and imported refrigeration system.

$ 5043.00

Temperature range -20~ 150 ℃, volume 225L, stainless steel studio and high-efficiency insulation material, support high and low temperature cycle test, suitable for aging test and pRoduct performance inspection.

$ 5399.00

Temperature range -20~ 150 ℃, studio volume 408L, suitable for high temperature and low temperature Reliability test, support constant temperature test, in line with a number of national standards.

$ 6076.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.

$ 6563.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision temperature control, the studio is made of 304 stainless steel.

$ 6575.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Determination of Static Surface Tension of Color Coatings Using the Platinum Plate Method with a Surface Tensiometer
This article introduces the method of measuring the static surface tension of colored paints using the platinum plate method. It explains the principle, which involves calculating the surface tension by measuring the force when the platinum plate is lifted from the liquid surface.
Correlation Analysis between Puncture Strength and Bursting Strength of Paperboard
This article analyzes the correlation between the puncture strength and burst strength of cardboard. The two properties respectively measure the ability of cardboard to resist dynamic impact and static pressure. Although their testing principles differ, both are closely related to factors such as the fiber structure and lamination process of the cardboard.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.