Paint film thickness Gauge Coating thickness Gauge

The paint film thickness gauge measures coating thickness non-destructively using magnetic induction or eddy current principles. The magnetic induction method is used for non-magnetic coatings on steel substrates, while the eddy current method is used for insulating coatings on non-ferrous metal substrates. It is applied in coating quality control and process validation.
Selection
Select between magnetic induction or eddy current principles based on the substrate type; ensure the measurement range covers the sample thickness; verify that the accuracy meets the process requirements; handheld devices are suitable for on-site measurements, while benchtop models are ideal for laboratory use; check the instrument calibration certificate and the configuration of standard calibration pieces.

Terms

Standards

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Battery-free, durable rare earth cobalt magnets, Measurement range 0 to 200 μm, accuracy +/- 1 µm (within 20 µm), with audible cues and wear-resistant carbide Probe.

$ 464.00

Measurement range 25~ 3000μm, step tooth design Division 25μm to 200μm, can be quickly placed vertically on the coating surface to measure the thickness immediately.

$ 93.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Made of stainless steel, the range is 10~ 100μm, Division 10μm, Dimension 65 * 36 * 1.5mm, suitable for Paints, varnish and other Coating Coating thickness measurement.

$ 119.00

With paint penetration measurement ability, accurate measurement of wall thickness without removing coatings, thickness range 2.5~ 125mm, accuracy +/- 0.03mm, support multi-echo and single-echo mode switching, suitable for detection needs of different surface conditions.

$ 2739.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement range 0-3000μm, error +/- 3%, easy to carry and high Stability, suitable for a variety of Coating thickness detection.

$ 461.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.