Super Circulation Constant Temperature Water Bath

The super-circulating constant temperature water bath drives liquid circulation through a pump, combined with heating and temperature control systems, to maintain a uniform and constant temperature of the liquid in the tank. It is used in scenarios requiring a stable temperature environment, such as constant temperature control for laboratory samples, reactor temperature regulation, and viscosity testing.
Selection
When selecting, consider whether the temperature range and accuracy meet the experimental requirements, check the compatibility of the tank capacity with sample dimensions, confirm that the circulation flow rate and pressure are suitable for the connection setup, inspect the safety protection features, pay attention to the material's corrosion resistance, and consider the convenience of daily maintenance.

Terms

Standards

Instruments

With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, resolution 0.1 ℃, pump flow rate 6L/min, to ensure temperature uniformity, support connection with external equipment.

$ 306.00

With dual functions of internal and external circulation, Temperature Fluctuation ≤ +/- 0.2 ℃, volume 20L, pump flow 6L/min, improve temperature uniformity and accuracy, suitable for connecting a variety of experimental equipment.

$ 330.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with a built-in circulating water pump to output thermostatic water flow, stainless steel structure to ensure durability and easy cleaning.

$ 367.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, with over-temperature water cut-off alarm function, built-in circulating water pump can output thermostatic water flow.

$ 622.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

With dual functions of internal and external circulation, Temperature Fluctuation is only +/- 0.05 ℃, resolution is 0.01 ℃, pump flow rate is 6L/min, ensuring temperature uniformity and corrosion resistance.

$ 391.00

With the function of water-oil dual-use, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field and support the establishment of a second thermostatic field for external circulation.

$ 564.00

Water and oil dual-use Temperature range, domestic circulation system with no heat centrifugal pump, Temperature Uniformity +/- 0.05 ℃, with multi-level Safety protection and optional program temperature control function.

$ 672.00

High temperature control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, equipped with circulating pump flow ≥ 4L/min, to ensure uniform water temperature, strong corrosion resistance, compact structure, suitable for a variety of experimental scenarios.

$ 302.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump and domestic circulation system, to ensure temperature stability and flow field uniformity, support a variety of Safety protection.

$ 559.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, support external circulation to establish a second thermostatic field, built-in multiple Safety protection devices.

$ 798.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range to 100 ℃, External circulation pump Flow rate 6L/min, Built-in Safety protection and optional program temperature control, suitable for a variety of experimental needs.

$ 1416.00

With dual-use function of water and oil, Temperature Uniformity up to +/- 0.05 ℃, Flow rate of external circulation pump 6L/min, liner with S304 stainless steel, Safety protection including power failure and low water level alarm.

$ 816.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, temperature control accuracy 0.01 ℃; no heat centrifugal circulation pump to avoid self-heating effect, porous U-shaped return design to achieve uniform turbulence; Equipped with multiple Safety protection and external circulation to establish a second thermostatic field.

$ 617.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.