Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Adopt double-pointer design, pressure needle Travel 0~ 2.5mm, measurement error +/- 1HAO, can be handheld or used with the bench, suitable for stable and fast detection of low Hardness rubber materials.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
Suitable for low and medium Hardness material measurement, pressure needle end pressure 0.55N-8.06N, pressure needle stroke 0-2.5 mm, can be matched with test rack to reduce manual operation error, improve test accuracy and Repeatability.
Travel 0-2.5 mm, measurement error +/- 1HA, can be used with a rack or hand-held operation to meet the requirements of standard test pieces and field object Hardness measurement.
Double pointer design can be used with rack or hand, pressing needle Travel 0-2.5 mm, measurement error +/- 1HA, suitable for rubber and plastic hardness testing.
With average value calculation and data latch function, support a variety of data output interfaces, Measurement accuracy of +/- 1H, suitable for testing rubber and plastic materials in different Hardness ranges.
Using 0.79mm truncated cone stylus, Measurement range 20-90HA, resolution 0.1HA, support metric system conversion and average calculation, integrated design is easy to carry.
Equipped with special fixed load weight, the total mass is about 1kg, and the downward pressure speed is 3.2mm/s, which can improve the Stability and accuracy of rubber Hardness measurement.
Measurement range 20~ 90A, error ≤ +/- 1H. With average value calculation, MAX Maximum latch function, support USB/RS-232 and Bluetooth Data output method.
With average value calculation and MAX Maximum latch function, support a variety of data output methods, Measurement range 10HA~ 90HA, resolution 0.1H, suitable for soft plastic, sponge and other hardness of materials detection.
Measurement range 0-100HD, recommended to use 20-90HD range, pressing needle stroke 2.5mm, pressing head SR0.1mm, can cooperate with the test rack to improve Measurement accuracy.
Pin Travel 0-2.5 mm, Measurement range 20-90HD, error +/- 1HD, weight only 0.16kg easy to carry, can be used with racks or handheld to meet different testing needs.
The all-in-one portable design weighs only 310g, supports metric and imperial unit switching, is equipped with average calculation and MAX Maximum latch function, Measurement accuracy ≤ 1HB, and can transfer data through USB/RS-232/Bluetooth interfaces.