Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.
Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.
Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Suitable for low and medium Hardness material measurement, pressure needle end pressure 0.55N-8.06N, pressure needle stroke 0-2.5 mm, can be matched with test rack to reduce manual operation error, improve test accuracy and Repeatability.
The imported central guide Rod material has high accuracy and abrasion resistance, the shell is made of super hard aluminum material to resist on-site damage, and the external spring coil pointer slider structure is easy to adjust the friction force. The nominal kinetic energy is 2.207J, and the strength measurement range is 20-60Mpa.
With -10 ℃~ 50 ℃ temperature range and 5% RH~ 98% RH Humidity range, accuracy of +/- 1.5 ℃ and +/- 5% RH, support unit conversion and automatic shutdown, easy and reliable operation.
Capacitive polymer film Humidity Sensor and semiconductor temperature sensor are used. The temperature error is +/- 0.2 ℃, Humidity error is +/- 2.0%, and wet bulb, dew point, dry bulb temperature switching and 99 groups of Data storage are supported.
Using split Sensor design, temperature range -20~ 60 ℃, humidity range 10~ 95% RH, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, compact and easy to carry.
Using Precision Digital Sensor, Measurement speed 0.4 seconds, Temperature range -20~ 60 ℃, Humidity range 10~ 95% RH, Small size and easy to carry, with MAX Maximum hold function.
Temperature range -10~ 50 ℃, Humidity range 5~ 98% RH, error as small as +/- 1.5 ℃, resolution 0.1, support unit conversion, portable and lightweight only 145g, suitable for a variety of environment monitoring.