Single-Sided Coating Applicator

A single-sided film applicator uses a fixed-gap blade to spread liquid onto a substrate, forming a uniform wet film. It is used in laboratories to simulate roller coating and blade coating processes, testing properties such as leveling and hiding power of coatings. It is suitable for quality control in industries such as inks and adhesives.
Selection
When selecting, consider the substrate thickness and coating requirements to match the gap specification of the film applicator. Stainless steel is wear-resistant, while carbon steel requires rust prevention. Choose the appropriate blade length based on the sample viscosity, and opt for a model with a handle for manual operation. Pay attention to the straightness and flatness of the blade.

Terms

Standards

Instruments

Single person single-sided vertical quasi-closed structure effectively prevents external gas induction, adjustable air volume system maintains 0.25~ 0.6m/s wind speed, equipped with double suspended Glass doors and convenient maintenance design.

$ 937.00

Spreader width 100mm, wet film thickness 37.5μm, wear-resistant corrosion-resistant alloy steel material, can be used manually or with automatic Film Applicator to ensure coating conformity and Repeatability.

$ 143.00

Spreader width 100mm, wet film thickness 40μm, wear resistant corrosion resistant alloy steel material, can be manually operated or with automatic Film Applicator to ensure coating conformity and Repeatability.

$ 143.00

Hardness stainless steel material, Hardness of 50~ 55HRC, film accuracy +/- 2μm, smooth surface to support a variety of Spreader requirements, can be used with Film Applicator to achieve automatic film operation.

$ 162.00

Spreader width 100mm, wet film thickness 400μm, wear-resistant corrosion-resistant alloy steel material, can be used manually or with automatic Film Applicator, suitable for preparing uniform film coating to test performance.

$ 143.00

Effective Spreader width 100mm, wet film thickness up to 600μm, high-quality wear-resistant corrosion-resistant alloy steel material, support manual film or with automatic Film Applicator to ensure good conformity Repeatability coating.

$ 143.00

Spreader width 100mm, wet film thickness 50μm, wear resistant corrosion resistant alloy steel material, suitable for manual or automatic Film Applicator, can be prepared uniform film for performance testing.

$ 143.00

Spreader width 100mm, wet film thickness 100μm, wear-resistant corrosion-resistant alloy steel material, can be manually operated or used with automatic Film Applicator, suitable for a variety of materials to prepare uniform film.

$ 143.00

Spreader width 100mm, wet film thickness 250μm, wear-resistant corrosion-resistant alloy steel material, can be used manually or with automatic Film Applicator, suitable for a variety of materials to prepare uniform film.

$ 143.00

Spreader width 100mm, wet film thickness 80μm, high-quality wear-resistant corrosion-resistant alloy steel material, support manual or automatic film, can be prepared uniform film coating for performance testing.

$ 143.00

Stainless steel material corrosion resistance, film thickness 2000μm high accuracy, application width 100mm to ensure uniformity, suitable for a variety of Coating tests.

$ 146.00

Spreader width 100mm, total length 130mm, wear-resistant corrosion-resistant alloy steel material, can be manually or automatically film, suitable for a variety of materials Preparative uniform film coating.

$ 143.00

Spreader width 100mm, wet film thickness 15μm, high-quality wear-resistant corrosion-resistant alloy steel material, can be manually or automatically film, suitable for a variety of materials Preparative uniform film coating.

$ 143.00

Spreader width 100mm, wet film thickness 500μm, high-quality wear-resistant corrosion-resistant alloy steel material, suitable for manual or automatic film, support non-standard customization to ensure uniform coating.

$ 143.00

Spreader width 100mm, wet film thickness 60μm, high-quality wear-resistant corrosion-resistant alloy steel material, manual film can also be equipped with automatic Film Applicator, support non-standard customization.

$ 143.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.