Permanent Gas Detection System

Fixed gas detectors continuously monitor the concentration of specific gases in the environment through sensors. When gases react with the sensors, causing changes in electrical signals, an alarm is triggered. They are used for leakage monitoring in places such as chemical plants and mines to ensure personnel safety.
Selection
When selecting, confirm that the type of gas to be measured matches the sensor type, consider whether the range and accuracy meet on-site requirements, check that the explosion-proof rating is suitable for the environment, ensure that the alarm values are adjustable, and pay attention to the sensor lifespan and maintenance cycle.

Terms

Standards

Instruments

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Support 4-20mA/RS485 signal input, provide 6 passive switching and sound and light alarm functions, operating temperature 0~ 40 ℃, compatible with two-wire and three-wire equipment, suitable for gas safety detection.

$ 259.00

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

Support 4 kinds of gas detection at the same time, integrated Humidity monitoring function, dual temperature Humidity compensation design, with 10 Meters visual distance high definition color screen, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 819.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.

$ 183.00

Support 4 kinds of gas simultaneous detection, integrated temperature Humidity monitoring, physical + software double revisit Humidity compensation, with zero automatic correction function, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS.

$ 1050.00

Adopting permanent magnet DC motor and augmented speed line to achieve 0-3000rpm stepless speed regulation, with 40W Power output, smooth operation and 120-minute timing function.

$ 123.00

Adopt permanent magnet DC motor, Power 140W, Speed range 0~ 1100rpm, support boosting function and unified speed regulation, and can still work stably in a solution with strong viscosity.

$ 490.00

Adopt permanent magnet DC motor to achieve stepless speed regulation, the speed range starts to 1100rpm, the four-station design can be synchronized Stir, enhance corrosion resistance, suitable for high viscosity solution treatment.

$ 993.00

Maximum support 4 kinds of gas simultaneous detection, integrated temperature and humidity monitoring and physical + software double compensation, using dual temperature and humidity design and 10 Meters visual distance high definition color screen, Protection Rating up to IP66 and operation temperature range -40~ 55 ℃.

$ 393.00

Support simultaneous detection of 4 gas paraMeters, integrated temperature and Humidity detection function, with Internet of Things remote monitoring capability, Response Time T90 meets national standards, Protection Rating up to IP66, adapt to -40~ 55 ℃ working environment.

$ 328.00

Adopting permanent magnet DC motor with augmented speed line to achieve stepless speed regulation of 0-3000rpm, with 160W Power output, smooth operation and no need to replace carbon brushes, medium speed stirring can reduce vibration and prolong life.

$ 199.00

Adopting permanent magnet DC motor with augmented speed line to achieve 0-3000rpm stepless speed regulation, with 100W Power output, smooth operation and no need to replace carbon brushes, medium speed stirring can reduce vibration.

$ 136.00

Articles

Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.