Adopt air jacket indirect temperature control to avoid condensation, dry moisture ratio control humidity Response fast, background concentration as low as formaldehyde ≤ 0.006mg/m ³, support automatic temperature control and humidity control and multiple safety protection, suitable for material environmental protection assessment.
The stainless steel inner box is used to ensure non-adsorption formaldehyde, the background concentration is as low as 0.006mg/m ³ and the holding time is long; Temperature range 15-40 ℃ accuracy +/- 0.5 ℃, humidity range 30-80% RH accuracy +/- 3%; low failure rate, the average initial maintenance interval exceeds 3 years.
Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with programmable Touchscreen controller, supports multi-stage program control and real-time data monitoring to ensure stable and reliable testing process.
Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.
Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.
Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.
It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.
Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -40~ 130 ℃, uniformity +/- 2 ℃, with 120 sets of programming and multiple Safety protection systems, support data communication and real-time monitoring.
Temperature range -40~ 130 ℃, Temperature Uniformity +/- 2 ℃, using fluorine-free environmental protection refrigerant and imported Compressor, with 120 groups of programmable control and independent temperature limit alarm system, support Interface for easy monitoring.
Temperature range -40~ 130 ℃ and uniformity +/- 2 ℃, using fluorine-free environmental protection refrigeration system, equipped with multi-stage programmable control and independent temperature limit alarm function to ensure the safety and stability of the experimental process.