Three-hole Digital Constant Temperature Water Bath

The three-hole digital constant temperature water bath heats the water tank through heating tubes, with the digital temperature controller adjusting the power in real-time. The three independent holes allow simultaneous constant temperature treatment of samples. It is used for constant temperature heating and reaction incubation of laboratory samples, maintaining stable temperature in scenarios such as coating viscosity testing and ink drying experiments.
Selection
When selecting, ensure the temperature range covers experimental needs, with temperature control accuracy typically within ±0.5℃. The aperture size should match common beaker specifications. Stainless steel material offers corrosion resistance, and the digital display interface allows straightforward operation. Safety features include over-temperature protection and grounding design, while heating power affects the heating speed.

Terms

Standards

Instruments

Using a sink structure, the maximum aperture of 12 cm, four circles per hole cover, heating tube placed in water to achieve rapid heating, Temperature range RT + to 100 ℃, temperature fluctuation +/- 1 ℃, Total Power 900W.

$ 248.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature range RT + 5~ 100 ℃, Temperature Fluctuation +/- 0.5 ℃, with timing function and over-temperature water cut-off alarm.

$ 412.00

With three sets of independent water Tanks and temperature control equipment, temperature can be set separately, temperature control accuracy +/- 0.3 ℃, resolution 0.1 ℃, stainless steel liner anti-corrosion easy to clean, over-temperature sound and light alarm to protect the sample.

$ 449.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

304 stainless steel one-time stretching liner has no water leakage, the four-corner arc design is heated evenly, the temperature fluctuation is +/- 0.5 ℃, the six-hole configuration meets various experimental needs, and the hidden outlet pipe is easy to operate.

$ 204.00

Double row six-hole design improves experimental efficiency, temperature control accuracy of +/- 0.5 ℃, Temperature Uniformity +/- 0.2 ℃, PID and fuzzy control technology to ensure temperature stability, stainless steel structure corrosion resistance and easy to clean.

$ 160.00

Double row four hole design to improve efficiency, temperature control accuracy of +/- 0.5 ℃, temperature fluctuation of only +/- 0.1 ℃, stainless steel corrosion resistance, electronic temperature control technology is stable and reliable, suitable for a variety of experimental heating needs.

$ 146.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
The adhesion tester employs a comparative analysis of methods including the cross-cut test, the scratch test, and the pull-off test.
This article compares three commonly used adhesion testing methods: the cross-cut test, the scratch test, and the pull-off test.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Comparison of the Three Principles of Paint Film Adhesion Testers
There are primarily three principles for paint film adhesion testers, and selection should be comprehensively considered based on the coating characteristics, substrate type, and testing purpose.
Process of Three-Roll Mill for Handling High-Viscosity Inks
This article introduces the process of using a three-roll mill to handle high-viscosity inks. It first explains that the equipment utilizes three rollers rotating at different speeds to grind materials through shearing and squeezing actions, making it suitable for high-viscosity systems.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
The impact of temperature, humidity, and vibration coupling in a three-environmental test chamber on the structural fatigue of products.
This article explores the impact of the coupled effects of temperature, humidity, and vibration in a three-comprehensive test chamber on the structural fatigue of products. It explains how such a coupled environment accelerates the degradation of material performance, such as high temperature and humidity reducing the material's fatigue limit, while vibration promotes crack propagation.
Differences between xenon arc lamps, carbon arc lamps, and UV lamps in automotive interior and exterior light aging tests
Xenon lamps, carbon arc lamps, and UV lamps are three commonly used light sources in the photodegradation testing of automotive interiors and exteriors. Xenon lamps can simulate the full spectrum of sunlight, and by adjusting filters, they can match different environmental conditions, making them suitable for comprehensive evaluation of material aging.