Fiber Optic Gas Detector

The fiber optic gas detector converts the attenuation of light signals at specific wavelengths absorbed by gas molecules into concentration data by measuring changes in light intensity. It is used for real-time monitoring of pipeline leaks and gas concentrations in chemical processes. In the petrochemical industry and environmental monitoring, it detects gases such as methane and hydrogen sulfide.
Selection
Select the corresponding spectral range based on the type of gas to be measured, and choose the model according to the on-site explosion-proof rating and temperature range. Consider the transmission distance to select the optical fiber type, compare the detection limits and response time parameters of different gases, and ensure the device is compatible with the existing control system interface.

Terms

Standards

Instruments

It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.

$ 154.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

Using white fiber filter element with black sieve structure, KF25 interface is suitable for pumping speed ≤ 6L/s Vacuumpump, which can effectively intercept oil and gas impurities, filter element can be cleaned and replaced, and maintenance is convenient.

$ 146.00

Maximum temperature up to 1700 ℃, Furnace volume 36L, using aluminum oxide fiber material and silicon molybdenum Rod heating element, equipped with a chill down system to ensure sealing performance, support inert or reducing gas environment sintering.

$ 6851.00

Operating temperature of 1400 ℃, Furnace volume of 36 liters, aluminum oxide fiber Furnace and double chill down system, support material sintering process in inert gas environment.

$ 4914.00

Using 8-bit micro control technology, Response Time is less than 60 seconds, equipped with 12864 point array LCD display gas concentration, with sound, light and vibration triple Alarm mode, Protection Rating up to IP65.

$ 235.00

Imported Electrochemical sensor, detection accuracy ≤ +/- 1%, Response Time ≤ 20 seconds; Support 1-5 kinds of gas detection at the same time, built-in powerful air pump, with Data storage and Temperature Humidity detection function.

$ 716.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Using 32-bit microprocessor and 24-bit ADC chip, support 1-6 Sensor expansion, with 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for gas monitoring in harsh environments.

$ 451.00

Ceramic fiber Furnace to achieve multi-faceted heating, Temperature uniformity less than +/- 5 ℃, heating rate ≥ 10 ℃/min, with nitrogen filling device to slow down oxidation and flue discharge of harmful gases.

$ 1937.00

Electrochemical sensor, detecting phosphating hydrogen gas, range 0-20ppm, resolution 0.1ppm, with sound, light, vibration triple alarm, IP65 Protection Rating, suitable for harsh environments.

$ 235.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 251.00

Using industrial grade Sensor to detect nitrogen dioxide gas, range 0~ 20ppm, resolution 0.1ppm, Response Time T90 < 60s, with waterproof, dustproof and explosion-proof characteristics, small and durable.

$ 248.00

Semiconductor Sensor to detect halogen gas leaks of less than 0.5 oz/year, Response Time ≤ 1 second, Sensitivity adjustable, Portable design weighing 250g, up to 9 hours of operation.

$ 109.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00

Articles