Paint protective layer Gloss Meter

The paint protective layer gloss meter evaluates the degree of gloss by measuring the ability of the coating surface to reflect light. The instrument emits a fixed-angle light beam onto the paint surface, receives the intensity of the reflected light, and converts it into gloss units. It is used to detect the gloss consistency of surface coatings on items such as automobiles and furniture, and to monitor the effectiveness of the spraying process.
Selection
When selecting, consider the measurement angles (20° for high gloss, 60° for general use, 85° for matte finishes) and ensure the instrument complies with standards such as ASTM D523. Check the validity of the calibration certificate and opt for a model with temperature compensation. Choose an appropriate probe based on whether the surface to be measured is curved or flat, and compare data repeatability across different brands.

Terms

Standards

Instruments

Multi-coil structure design, protective layer thickness Measurement range 1-185mm, accuracy +/- 1mm, with four scanning modes and ultra-dense rib resolution, support one-hand grip operation.

$ 904.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Using standard sand free fall brushing layer, straight grinding to expose 4mm substrate; can quantify the abrasion per unit thickness of the paint layer of sand volume, the inner diaMeter of the catheter 19mm, sample holder 45 degrees angle fixed.

$ 538.00

Multi-coil structure design to improve the detection speed and accuracy, protective layer thickness Measurement range is 6-50mm, built-in lithium battery supports 20 hours standby, Handheld ergonomic design is easy to operate on site.

$ 304.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

Three grid irreversible discoloration design, temperature point 50 ℃, 60 ℃, 70 ℃, each piece size 12x30mm, with protective film to enhance durability, easy to paste and carry.

$ 150.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Demoulding design reduces the accumulation of paints, with 4mm hanging holes for non-marking suspension, protective film to prevent scratches and corrosion, size 260x239x0.8mm, in line with a number of international test standards.

$ 504.00

Contains 216 Classic Colors, semi-matte surface, full page color sample size 5.0x15.0cm, monochrome design for easy comparison, with U-shaped protective cover for loss prevention.

$ 145.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Adopt 45 ° circular lighting structure, reduce texture effect, compatible with 60 ° Gloss measurement, Repeatability Delta E * ab 0.03, built-in high Sensitivity Sensor, suitable for matte and textured material surfaces.

$ 6334.00

Impact energy 3N, Impact device mass 75g, suitable for measurement of small or thin specimens and surface hardening layer, the minimum thickness can be measured 1mm and the minimum hardening layer depth 0.2mm.

$ 764.00

The three-angle measurement design covers 20 °/60 °/85 °, the measurement range is 0.1~ 200GU, the repeability is +/- 0.5GU, and 254 sets of data storage and Bluetooth output are supported to meet the needs of surface Gloss detection of various materials.

$ 336.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 1000GU, Repeatability 0.2GU, support USB and Bluetooth interface, can store 10000 sample data, suitable for surface Gloss measurement of various materials.

$ 332.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.