High-low temperature circulation Bath

The high-low temperature cycling bath controls the liquid temperature inside the tank through a refrigeration and heating system, allowing the samples to undergo cyclic changes within the set temperature range. It is used for testing material properties such as thermal expansion and contraction, aging, and is commonly applied in environmental adaptability tests for electronic components and chemical products.
Selection
When selecting, consider that the temperature range covers experimental needs, the temperature control accuracy meets standards, the tank capacity fits the sample size, the medium viscosity is compatible with the sample, the device stability meets long-term operation requirements, and safety protection features are comprehensive.

Terms

Standards

Instruments

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

The centrifugal circulation pump without heat is adopted to reduce the influence of temperature field, and the U-type reflux circulation realizes Temperature Uniformity +/- 0.05 ℃. It has safety devices such as power-off protection and low water level alarm, and can choose multi-stage temperature control program.

$ 1222.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.

$ 7243.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1703.00

Temperature range -30~ 25 ℃, Temperature Stability +/- 2 ℃, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, high temperature lifting speed, can provide large Flow rate circulation and multi-functional low temperature operation support.

$ 2541.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1335.00

8L Tank with -10~ 100 ℃ wide Temperature range, equipped with maintenance-free pressure pump to achieve two-way mixing, support single point and two point temperature calibrating, with low level protection and high temperature protection function.

$ 1122.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control and High Accuracy PT100 Sensor to ensure stability and accuracy.

$ 1408.00

With heating and cooling function, Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, Pump Flow rate 12L/min, Support internal and external circulation and remote communication, corrosion resistant design.

$ 974.00

Using non-fluorine environmental protection Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor. The domestic circulation system avoids the heat generation of the water pump from affecting the temperature field, supports multi-capacity optional, Safety protection functions are complete.

$ 1264.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, integrates PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, and has multiple safety functions such as low water level protection and temperature loss alarm.

$ 1416.00

8L Tank Volume, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, with low liquid level protection and automatic power failure recovery function, support internal and external circulation operation.

$ 1542.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ° C. It has safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.

$ 6070.00

Temperature range -30~ 100 ℃, temperature resolution 0.1 ℃, fully enclosed Compressor refrigeration and overheating overcurrent protection, stainless steel liner for easy cleaning, equipped with high-performance heat-free centrifugal circulation pump.

$ 1493.00

The non-heat centrifugal circulating pump is adopted to avoid its own heat generation affecting the temperature field. The U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, and has multiple safety devices such as low water level protection and temperature loss alarm.

$ 5621.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.