Pendulum Damping Test Instrument

The pendulum damping tester measures the softness or hardness of a coating by observing the rate of amplitude decay as the pendulum swings on the coating surface. The greater the resistance encountered by the pendulum swing, the softer the coating. It is used to detect changes in hardness during the drying process of coatings and inks.
Selection
When selecting a pendulum damping tester, it is essential to consider the measurement range to match the hardness of the coating, the pendulum type to comply with testing standards, the instrument's accuracy to meet inspection requirements, the ease of operation to align with user habits, and the structural stability to ensure long-term reliability.

Standards

Instruments

Equipped with 200 +/- 0.2g Koenig pendulum and 500g platinum saz pendulum two configurations, the swing period is 1.4 +/- 0.02s and 1 +/- 0.001S, through the photoelectric system automatic measurement of film damping time, to meet the different standards of test requirements.

$ 742.00

Equipped with 200 +/- 0.2g and 500 +/- 0.1g two swing bars, can measure the film damping time, reflect the surface Hardness through swing attenuation, support different standard test requirements.

$ 582.00

Adopting Koenig pendulum structure, the total mass is 200 +/- 0.2g, and the swing period is 1.4 +/- 0.02s. The coating Hardness is accurately measured by the swing attenuation time, and the number of swing angles is automatically recorded.

$ 519.00

Using Konig swing Rod, mass 200g, swing period 1.4 +/- 0.02s, can swing 250 +/- 10s on flat Glass, suitable for coating damping test, accurate measurement Hardness change.

$ 496.00

It can be equipped with 200 +/- 0.2g and 500g swing Rods, providing 1.4 +/- 0.02s and 1 +/- 0.001s swing cycles respectively, and accurately determines the film Hardness through damping time to adapt to different coating resilience and viscosity characteristics.

$ 531.00

Konig and Persoz swing bars are used, Konig swing period is 1.4s, Persoz swing period is 1s, and the number of swing angles is automatically recorded, which is suitable for accurate determination of paint film Hardness.

$ 654.00

Using the electromagnet cissing pendulum, it can measure the thickness of the test plate from 0.1mm to 5.5mm, and is equipped with two laser Probes to record data. The swing period is 0.625s.

$ 1427.00

Support Koenig and Persaz double pendulum automatic switching, steel ball diaMeter 5mm and 8mm, with electromagnetic release and electronic counting mechanism to ensure that the test is accurate and not affected by the environment.

$ 11377.00

Using electromagnet cissing pendulum, equipped with two laser Probe to record data, the thickness range can be measured 0.1-5 mm, the organic Glass door cover reduces the influence of airflow, and the swing period is 1 second.

$ 1411.00

Using electromagnet cissing pendulum, equipped with two laser Probe recording data, can test 0.1mm to 5.5mm thickness test plate, swing period 1.4s, Organic Glass door cover to reduce the impact of airflow.

$ 1411.00

Using stopwatch counting method, the length of the swing Rod is 500 +/- 1mm, and the total mass of the swing is 120 +/- 1g. The resistance to deformation is evaluated by measuring the ratio of the swing amplitude time on the film to the swing time on the Glass.

$ 248.00

Support Koenig and Persaz two test methods automatic switching, ball diaMeter of 5mm and 8mm, equipped with electromagnetic release system and sound and light prompt function, to ensure Test accuracy and ease of operation.

$ 11377.00

Measurement accuracy is ensured by the automatic counting function and the coating attenuation characteristics are determined by the stainless steel ball support.

$ 1698.00

It can measure the impact toughness of hard plastics and Non-metallic materials, with a pendulum energy of 2.75J to 11J, an impact speed of 3.5m/s, and a test angle of 150 °. The structure is simple and easy to operate.

The electromagnet cissing pendulum is used, which can adapt to the thickness test plate of 0.1mm to 5.5mm, and is equipped with two laser Probe to record data. The swing period is 1.4 seconds and 1 second respectively, and the organic Glass door cover reduces the influence of airflow.

$ 1475.00