Dual-track fineness Gauge

The dual-channel fineness gauge is used to spread a sample through a wedge-shaped groove with calibrated scales, and the particle size is determined by observing the scale value corresponding to the location where particles become visible. It is employed in industries such as coatings and inks to assess the dispersion degree of pigments or fillers and to ensure consistency in product fineness.
Selection
When selecting, consider matching the particle size range of the material being measured with the scale range. The stainless steel material ensures wear resistance, and the machining precision of the wedge-shaped groove affects the accuracy of readings. The operating environment requires a flat and clean work surface, and a standard scraper should be used to apply force evenly.

Terms

Standards

Instruments

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-25μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Made of Hardness 52 +/- 2HRC wear and corrosion resistant alloy steel with 0-100μm range and 5μm Graduation, the single-channe design meets several international standards for a wide range of material particle Fineness measurement.

$ 172.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-250μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1531.00

Double groove design can achieve rapid fineness detection, Measurement range 0~ 100μm, accuracy +/- 2 microns, wear-resistant and anti-corrosion stainless steel material, suitable for a variety of material fineness determination.

$ 1086.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-15μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-100μm, suitable for particle size and fineness of grinding inspection, ergonomic design for easy grip.

$ 1157.00

Measurement accuracy of +/- 2 microns, wear resistance and corrosion resistance, handheld operation, suitable for rapid detection of various material fineness.

$ 1086.00

Stainless steel is more durable, with a length of 75mm, suitable for all models of GrindoMeter, and meets ASTM D1210, DIN 53203 and other standards to ensure accurate fineness measurement.

$ 549.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-50μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1157.00

Made of Swiss tool steel, Abrasion Resistance and corrosion resistance are excellent, accuracy reaches +/- 2 microns, wide groove design is easy to handle, suitable for a variety of material fineness detection.

$ 1323.00

Double groove structure can be measured twice at the same time, Measurement range 0~ 25μm, accuracy +/- 2μm, hardened stainless steel material wear and corrosion resistance, suitable for a variety of material fineness detection.

$ 1086.00

Made of Swiss 1.2805 tool steel, Abrasion Resistance and corrosion resistance are excellent; the accuracy reaches +/- 2 microns, the groove width is 37mm, and the graded slope design is easy to quickly read the fineness value.

$ 1323.00

Made of wear-resistant and anti-corrosion Swiss tool steel, the accuracy reaches +/- 2 microns, and the wide 37mm groove design is easy to handle, suitable for rapid determination of fineness of various materials.

$ 1323.00

Made of Hardness 52 +/- 2HRC alloy steel, with a range of 0-150μm and a Graduation of 7.5μm, it has wear and corrosion resistance and is suitable for Fineness measurement of various materials.

$ 172.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.