Water Bath heater

The water bath heater heats the water medium through an electric heating tube, utilizing water to conduct heat and ensure uniform heating of the samples. It is used in laboratory settings for constant-temperature heating and dissolution reactions of samples, preventing denaturation caused by direct heating.
Selection
When selecting, consider that the temperature range covers experimental needs, the capacity matches the number of samples, and the temperature control accuracy meets experimental standards. The material should be corrosion-resistant, with safety features including dry-burning protection and overheating protection.

Terms

Standards

Instruments

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

The special forming process heater has no warpage deformation at high temperature, excellent corrosion resistance of the spray panel, uniform working surface temperature, Heating power 2 × 1000KW, rapid and safe heating.

$ 128.00

The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.

$ 2300.00

Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.

$ 871.00

It has the function of water shortage and air burning and independent temperature limiting system, temperature control accuracy +/- 0.3 ℃, adopts one-time stamping forming stainless steel liner, supports internal and external circulation and timing operation.

$ 459.00

Equipped with round water Bath cover and aluminum Cup body, flow hole diaMeter 5.6mm, capacity 50ml, in line with GB/T1723 standard, suitable for viscosity measurement.

$ 152.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Adopt electromagnetic pump circulation mode, Temperature range 5~ 80 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with water shortage protection function to prevent accidents, support a variety of interface connections.

$ 433.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Articles

Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.