Using diffuse transmission optical path design, optical density Measurement range 0.00-6 OD, light transmitance accuracy +/- 2%, can simultaneously measure light transmitance, absolute optical density, relative optical density and Dot area ratio.
Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.
The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.
Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.
The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.
Optical inspection encoder is used for accurate measurement of tear angle, with dual gear Measurement range 50~ 16000mN, supports simultaneous testing of 4-layer samples, and is suitable for sheet composite strength analysis.
The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.
Using photoelectric detection and microcomputer servo system, high Sensitivity, minimum reading +/- 0.005 °, Repeatability ≤ 0.007 °, low optical rotation samples with measurable transmittance ≥ 10%, no reading error.
Optical inspection system with dual beam of light feedback compensates for Illuminant fluctuation in real time, Light spectrum reflectance Repeatability Standard Deviation is less than 0.1%, and the inter-device difference Delta E * ab is as high as 0.08, which can accurately measure fluorescent materials without UV correction.
Optical inspection fluorescence method without reference solution, built-in temperature sensor to calibrate data in real time, dual range design covering 0~ 20mg/L and 0~ 200% Saturation, 10 Meters long cable to support deep water or remote installation, polyformaldehyde and stainless steel composite structure to enhance environmental adaptability.
It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.
Measurement principle of diffuse transmission, optical density Measurement range of 6.000 OD, accuracy +/- 0.02 OD, equipped with fixed seat and bracket, support two Measurement mode, suitable for translucent material testing.
The sampling size of the equipment is 300 * 320mm, and the parallelism of the incision is less than or equal to 0.1mm. It can accurately detect the mechanical properties such as paper tension resistance, elongation and fracture length, and meets the requirements of many national standards.
Measurement range 10~ 500mN, resolution 5mN, tear arm 104mm, paper size 25 * 15mm, suitable for accurate determination of paper Tear strength.
Optical inspection system with infinity, 40X-1000X magnification range and N.A.1.25 Abbe condenser, support digitalization observation and a variety of auxiliary equipment expansion.