Gas densitoMeter

Gas densimeters measure gas density based on the principle of buoyancy or changes in vibration frequency. By detecting the physical effects of gases on a float or vibrating element, they directly convert these effects into density values. They are used for calculating the calorific value of natural gas, detecting the purity of industrial gases, and monitoring environmental emissions.
Selection
Select the corresponding range based on the type of gas being measured, and use corrosion-resistant materials for corrosive gases. Consider the compatibility of operating pressure and temperature ranges with the working conditions, ensuring the accuracy meets process control requirements. Portable devices are suitable for on-site inspections, while online systems are used for continuous monitoring.

Terms

Standards

Instruments

Adopt horizontal press measurement and physical positioning observation window, density Repeatability ≤ 0.001D, chroma Repeatability dE * ab ≤ 0.03, provide nearly 30 kinds of Measurement parameters and more than 30 kinds of evaluation Illuminants, and support connection PC software and mobile end applications.

$ 3285.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.

$ 154.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Using 8-bit micro control technology, Response Time is less than 60 seconds, equipped with 12864 point array LCD display gas concentration, with sound, light and vibration triple Alarm mode, Protection Rating up to IP65.

$ 235.00

Using 32-bit microprocessor and 24-bit ADC chip, support 1-6 Sensor expansion, with 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for gas monitoring in harsh environments.

$ 451.00

The imported movement motor has strong Power, the exhaust capacity is 456L/min to meet the high efficiency demand, the noise is only 53dB, and the operation is quiet. The gas storage Tank is treated with anti-rust and anti-bacterial treatment to ensure that the gas is clean.

$ 1689.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Using corrosion-resistant PVC material and titanium alloy heating tube, Temperature Uniformity ≤ +/- 2 ℃, equipped with sulfur dioxide flowMeter and alkali waste gas treatment system to ensure test accuracy and environment safety.

$ 15823.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 251.00

Imported Electrochemical sensor, detection accuracy ≤ +/- 1%, Response Time ≤ 20 seconds; Support 1-5 kinds of gas detection at the same time, built-in powerful air pump, with Data storage and Temperature Humidity detection function.

$ 716.00

Using industrial grade Sensor to detect nitrogen dioxide gas, range 0~ 20ppm, resolution 0.1ppm, Response Time T90 < 60s, with waterproof, dustproof and explosion-proof characteristics, small and durable.

$ 248.00

Articles

Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Application of Solvent Rub Tester in the Coatings Industry
The solvent rub tester is a detection device used to test how many times a coating surface can withstand solvent rubbing without being damaged, thereby evaluating the curing quality, durability, and cross-linking density of the coating.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.