pH Conductivity Test Pen

The pH conductivity test pen measures pH value through the glass electrode sensing hydrogen ion concentration, and obtains conductivity via the metal electrode measuring the solution's electrical conductivity. It is used for on-site rapid detection of liquid acidity, alkalinity, and ion content, suitable for fields such as water quality monitoring and chemical reaction control.
Selection
Select the pH 0-14 or conductivity 0-200 mS/cm specification based on the measurement range; consider the accuracy requirement of 0.01 pH or 1%; check for temperature compensation and automatic calibration functions; confirm that the electrode material is suitable for strong acid and alkali environments; choose an IP67 protection rating for humid scenarios.

Terms

Standards

Instruments

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Support pH, conductivity and other 7 paraMeter measurement, accuracy of 0.001 level, with 3000 data storage and IP57 protection, Type-C charging interface for outdoor use.

$ 562.00

Support pH, conductivity, TDS and other seven paraMeter measurement, Data storage 450 groups, with automatic temperature compensation and ElectRode diagnostic function, dustproof and waterproof grade IP54, Measurement accuracy of +/- 0.01pH.

$ 772.00

Equipped with 7-inch high-resolution Touchscreen, supports 1000 sets of Data storage, pH1-5 point Automatic calibration and conductivity 1 point Adjustment, provides automatic temperature compensation and ElectRode diagnosis.

$ 1324.00

Glass bulb sensitive film, Measurement range 0-14pH, suitable for low Conductivity Detector sample measurement under closed static conditions, Dimension Φ 12 × 120mm.

$ 89.00

Built-in three measurement units can simultaneously detect pH, Conductivity Detector and dissolved oxygen, support automatic temperature compensation and ElectRode diagnosis, with IP54 Protection Rating, data storage capacity of 500 groups, support GLP specification to achieve data traceability.

$ 1142.00

Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with temperature compensation function, portable design for easy field use, large screen LCD display is clear and intuitive.

$ 114.00

Measurement range 0.00-14 pH, accuracy +/- 0.05pH, with automatic temperature compensation function, portable design for on-site fast detection, repeatability error only +/- 0.03.

$ 105.00

Measurement accuracy of +/- 0.1pH with three-point calibrating technology, PH and temperature can be measured simultaneously, compact and portable, suitable for outdoor use.

$ 107.00

Support 0.00-14 pH and 0.00-10 mS/cm conductivity measurement, automatic temperature compensation, 24-hour continuous monitoring, high and low alarm LED indication, Data storage interval of 15 minutes.

$ 769.00

Using external ElectRode design, Measurement accuracy of 0.01pH, support 0.1-14 pH range and 0-50 ℃ temperature measurement, small size for on-site detection and operation.

$ 112.00

Using microprocessor control, pH Measurement accuracy of +/- 0.02pH, support three point calibrated (4.01, 6.86, 9.18), simple operation, stable and reliable performance.

$ 107.00

Using planar pH ElectRode design, Measurement accuracy of 0.01pH, Support 1-3 point Automatic calibration, with automatic temperature compensation and end point locking function, full waterproof structure to ensure harsh environment use.

$ 178.00

Fast Response with Planar pH ElectRode, Automatic temperature compensation and 1-3 point Adjustment, Measurement accuracy of 0.01 pH, Support automatic end point locking and full waterproof design.

$ 173.00

Articles

Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Classification standards for determining the hardness of coatings using a pencil hardness tester.
This article introduces the method of measuring the hardness of coatings using a pencil hardness tester. It involves using pencils of varying hardness to scratch the coating and observing whether scratches are produced to determine the hardness grade, ranging from 6B to 9H.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Key Operational Points and Influencing Factors of Pencil Hardness Method for Determining Coating Film Hardness
The pencil hardness test is a method used to evaluate the scratch resistance of a coating by making marks on the paint film with pencils of known hardness. During the operation, a uniformly cured sample is prepared, and calibrated pencils are used to make marks at a 45-degree angle with a fixed force, aiming to identify the highest hardness grade that does not scratch through the paint film.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.