Liquid Solution TensioMeter

The solution Tensiometer evaluates wettability and spreadability by measuring the surface tension of liquids. Its principle is based on the tension experienced by a platinum plate or ring on the liquid surface. It is used to guide the adjustment of coating and ink formulations and is applied in printing and papermaking to control ink clarity and the effectiveness of plastic surface treatments.
Selection
When selecting a solution Tensiometer, consider a measurement range that covers the sample's tension values, precision that meets industry standards, ease of operation for daily use, compatibility with common solvents, low maintenance requirements, and easy availability of accessories to ensure long-term stable operation.

Terms

Standards

Instruments

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.

$ 135.00

The composite design can be filled with internal reference solution, equipped with annular ceramic liquid junction and circular Glass sensitive film, Measurement range 0-14pH, Operating temperature 0-80 ℃, to ensure long-term measurement Stability.

$ 143.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

General ion standard solution with concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily calibrating needs.

$ 135.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

General ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE solution bottle Encasement, capacity 480mL, water Hardness type.

$ 135.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily ion calibrating.

$ 135.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.

$ 135.00

Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.

$ 96.00

Using open liquid complex structure, equipped with solid polymer reference electrolysis solution, the membrane resistance is less than 200MΩ, suitable for -5~ 80 ℃ wide temperature environment, to ensure long-term stable measurement.

$ 243.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Concentration 1000ppm, Encasement with PTFE solution bottle, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy and Stability.

$ 135.00

The pRoduct concentration 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Calcium Ion concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Determination of Static Surface Tension of Color Coatings Using the Platinum Plate Method with a Surface Tensiometer
This article introduces the method of measuring the static surface tension of colored paints using the platinum plate method. It explains the principle, which involves calculating the surface tension by measuring the force when the platinum plate is lifted from the liquid surface.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.