With -10 ℃~ 50 ℃ temperature range and 5% RH~ 98% RH Humidity range, accuracy of +/- 1.5 ℃ and +/- 5% RH, support unit conversion and automatic shutdown, easy and reliable operation.
Capacitive polymer film Humidity Sensor and semiconductor temperature sensor are used. The temperature error is +/- 0.2 ℃, Humidity error is +/- 2.0%, and wet bulb, dew point, dry bulb temperature switching and 99 groups of Data storage are supported.
Using split Sensor design, temperature range -20~ 60 ℃, humidity range 10~ 95% RH, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, compact and easy to carry.
Using Precision Digital Sensor, Measurement speed 0.4 seconds, Temperature range -20~ 60 ℃, Humidity range 10~ 95% RH, Small size and easy to carry, with MAX Maximum hold function.
Temperature range -10~ 50 ℃, Humidity range 5~ 98% RH, error as small as +/- 1.5 ℃, resolution 0.1, support unit conversion, portable and lightweight only 145g, suitable for a variety of environment monitoring.
Temperature range -40~ 70 ℃, Humidity range 20~ 90% RH, built-in Sensor design, support unit conversion, portable and lightweight, suitable for a variety of environment monitoring needs.
The device can continuously measure up to 10,000 hours, temperature range -20~ 70 ℃, Humidity range 0~ 100% RH, with backlight display and automatic shutdown function, built-in Probe for easy operation.
Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, resolution up to 0.1 ℃ and 1% RH.
Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, equipped with 9V battery power supply.
Using split Sensor design, the temperature range covers -50~ 70 ℃, Humidity Measurement range 20%~ 99% RH, supports ℃/F unit conversion, which is convenient for indoor and outdoor environment monitoring.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.
Adopt precision automatic control and data collection system to achieve full digitalization adjustment; with 1-400mm/min speed range and +/- 0.5% force value accuracy, support tensile compression bending and other test modes.
Full digitalization adjustment with precision automatic control, support 1-400mm/min speed range and 0.5% force value accuracy, with multiple test modes and real-time Linear dispersion display function.
With 200N range and 1-400mm/min speed range, automatic data collection system, support for tensile compression test and real-time display of force-deformation Linear dispersion, automatic calculation of 10 specimen statistics.