Nitrogen Determination Digester

The nitrogen digestion apparatus decomposes samples by heating with sulfuric acid, converting organic nitrogen into ammonium salts. It is used to determine the nitrogen content in materials such as coatings and plastics, and is employed in the paper and ink industries for the analysis of raw material composition.
Selection
Consider sample type and throughput requirements when selecting. Check heating temperature control accuracy and corrosion resistance. Match laboratory power specifications. Confirm safety protection devices are complete. Compare consumables compatibility across different models.

Terms

Standards

Instruments

Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.

$ 493.00

The equipment supports manual automatic dual mode switching, distillation speed of 3~ 6 minutes per sample, collection rate ≥ 99.5%, with automatic filling of lye and Boricacid absorption liquid function, as well as fault detection and real-time monitoring system.

$ 2925.00

Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.

$ 212.00

15 minutes to quickly heat up to the set temperature, temperature control accuracy of +/- 0.5 ℃, using multi-point calibrated to eliminate temperature errors, standard imported Glass digestion tube resistant to sudden cooling and sudden heating without bursting.

$ 522.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Double needle automatic switching angle to improve condensing efficiency, support 1-8 bit Sample Handling, temperature control accuracy of +/- 0.5 ℃, with independent nitrogen channel and overheating protection to ensure safe and stable operation.

$ 7496.00

Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.

$ 4688.00

Using purge and trap technology, the temperature control accuracy can reach +/- 0.5 ℃, 12 samples can be processed simultaneously, and the nitrogen consumption can be adjusted at 330ml/min/sample to achieve rapid anaerobic condensation.

$ 430.00

Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, support 36 samples at the same time, nitrogen consumption can be adjusted to 330ml/min/sample, digital temperature control to ensure accurate and reliable operation.

$ 719.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.

$ 1493.00

Using Dynamic Low Temperature Nitrogen Adsorption Method and High Sensitivity Sensor, the test range from 0.0005m ²/g has no upper limit, the repeatability error ≤ +/- 3%, and the single sample test is completed in about 3 minutes.

$ 7980.00

Articles