Halogen light source color comparison box

A halogen light source color matching booth uses halogen tungsten lamps to simulate daylight spectrum, providing a standard light source environment to ensure consistent visual evaluation of sample colors. It is used for color comparison and quality control in industries such as coatings and plastics, preventing metamerism.
Selection
When selecting, consider that the light source type must comply with industry standards, illumination uniformity should be stable, the chamber dimensions must fit the sample size, the viewing angle should be configured according to specifications, the operation interface should be simple and user-friendly, and maintenance costs must be balanced with equipment lifespan.

Terms

Standards

Instruments

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Featuring a 45°/0° illumination method and full-spectrum LED light source, it has an 8mm measurement aperture with a standard deviation ΔE*ab of less than 0.03, ensuring excellent repeatability. The built-in compensation optical path ensures data stability, eliminating the need for frequent calibration. Compact and portable, its size is comparable to that of a lipstick.

$ 130.00

Configuration of 6 Standard light sources including D65 and UV Illuminant, equipped with 45 degree observation station to achieve 45/0 observation conditions, no need to warm up without flashing, high luminous efficiency Color evaluation fast and reliable.

$ 1171.00

Using high color rendering index CRI = 98 D65 light source, equipped with 4 36W lamps and light source Timer, all-metal structure to ensure stable and uniform light, in line with ISO3664 international standards.

$ 1735.00

It adopts all-metal sheet metal structure, equipped with 4 18W high color rendering lamps, with a color rendering index of more than 95, with Illuminant Timing function, and the inclined operation table conforms to human visual observation habits.

$ 1074.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

The all-metal sheet metal structure is sturdy and stable, equipped with 36W × 4 Graphica imported lamps, with a color rendering index CRI ≥ 95, uniform lighting and Illuminant Timer, and the inclined surface console conforms to visual observation habits.

$ 1639.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.