Light Transmittance Haze Analyzer

The transmittance haze meter measures the total transmitted light and scattered light components by illuminating the sample with a light source, and calculates the transmittance and haze values accordingly. It is used to evaluate the transparency and blurriness of transparent materials and finds applications in quality inspection of plastic films and glass products.
Selection
Ensure the measurement range covers sample transmittance of 0-100% and haze of 0-30%, and use an optical system compliant with ASTM D1003 standards. Consider sample thickness adaptability and fixture type, and perform regular calibration with standard plates. Choose manual or automatic models based on testing volume, and ensure the working environment is vibration-proof and dust-proof.

Terms

Standards

Instruments

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.

$ 11337.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.

$ 20729.00

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy to achieve High Accuracy Transmittance and haze measurement, Repeatability is less than 0.05, Support a variety of observation Illuminant and dynamic temperature monitoring.

$ 7464.00

Adopt LED Illuminant to achieve 0~ 100% measurement range, resolution up to 0.1, support single continuous measurement mode, lightweight structure only 100g, can be through USB/RS-232/Bluetooth multi-mode data transmission.

$ 380.00

Compact and portable, supports three Standard light sources and dual light path design, measurement resolution up to 0.01, Repeatability ≤ 0.02, data cloud storage can be connected through the mobile phone Mini Program.

$ 557.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving system, the light transmitance haze accuracy is up to 0.01%, with A/C/D65 three light sources and vertical-lying dual-use observation mode, support USB interface data export, LED light source long life fast start.

$ 2010.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Light spectrum LED Illuminant and Light spectrum Sensor, equipped with 14mm and 5mm dual measurement aperture, haze Repeatability ≤ 0.03, with open measurement area to support liquid and large size sample detection.

$ 1455.00

Using 256 pixel dual array CMOS image sensor to achieve 0.01 unit haze resolution; Equipped with dynamic measurement function, real-time monitoring of environment changes to ensure data Reliability; Open measurement area supports vertical horizontal test.

$ 7464.00

It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.

$ 341.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

Compact and portable, with a resolution of 0.01, Repeatability ≤ 0.02, supports three measurement diameters and three Standard light sources, meeting a variety of Sample sizes and test standards.

$ 396.00

Articles

Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.