High Temperature Peel Strength Tester

The high-temperature peel strength tester measures the force required to separate the adhesive layers of materials at a set temperature. By using a heating platform to simulate actual usage environments, it is used to test the adhesive performance of materials such as tapes and films under high-temperature conditions. It is commonly employed in quality inspections within the packaging and electronics industries.
Selection
When selecting, consider the test temperature range and ensure the sample size matches the equipment chamber, confirm that the sensor range covers the expected peel force values, check the temperature control accuracy and uniformity, ensure the fixtures are compatible with the material type, and pay attention to whether the data acquisition frequency meets the requirements of the testing standards.

Terms

Standards

Instruments

Adopt stepper motor to achieve stepless speed regulation of 1~ 500mm/min, equipped with 500N force value Measurement range and +/- 1% accuracy level, with overload protection and limit protection functions, stable and reliable operation.

$ 1663.00

Using precision screw pair and servo motor drive, the test speed range is 1~ 500mm/min, the effective stroke is 800mm, with overload protection and limit protection functions, and the operation is stable and reliable.

$ 1663.00

Measurement accuracy of 0.5 with High Accuracy Sensor, speed range 5~ 500mm/min, support automatic Linear dispersion analysis and multi-point data collection, tensile, tear and disbonding tests.

$ 1645.00

Maximum load 50Kg, Test speed 10~ 60mm/min adjustable, using pointer sensing mode, effective Travel 0~ 360mm, suitable for vertical angle disbonding test.

$ 716.00

The High Accuracy Sensor is used to achieve 0.5 level Measurement accuracy, supports 5~ 500mm/min speed range, and is equipped with automatic Linear dispersion analysis function, which can calculate interval results and distinguish MAX Maximum, MIN Minimum and Average.

$ 1645.00

With 0.5 accuracy and 5~ 500mm/min speed range, using High Accuracy Sensor and stepper motor control, support automatic Linear dispersion analysis and multi-interval result calculation, effective Travel up to 400mm.

$ 1645.00

With 0.5 accuracy and 200kg capacity, it supports a variety of disbonding tests such as 180 ° and 90 ° disbonding, automatically records Linear dispersion and analyzes MAX Maximum, MIN Minimum and Average for a variety of material inspections.

$ 1645.00

With 0.5 levels of accuracy and a speed range of 5-500mm/min, it supports automatic drawing of disbonding Linear dispersion and calculation of interval results, and can resolve MAX Maximum, MIN Minimum and Average for a variety of material tests.

$ 1645.00

With 0.5 accuracy and 5~ 500mm/min speed adjustment range, it supports automatic drawing of disbonding Linear dispersion and calculation of interval results. It can distinguish MAX Maximum, MIN Minimum and Average, and effectively Travel up to 400mm.

$ 1645.00

Full digital control AC motor, speed accuracy of 0.5%; aluminum extrusion sealing plate built-in double roller screw structure, Test speed range of 0~ 300mm/min, with upper and lower limit and overload protection function.

$ 1343.00

Precision ball screw drive system, Force Measurement range 0.005-30N, Accuracy grade 0.5, equipped with 5-inch high definition Touchscreen and intelligent operation function, support a variety of unit selection and USB data export.

$ 1590.00

Can measure 20~ 1000J/m ² Internal Bond Strength, resolution of 0.001lbf/in ², using 90 ° Impact Angle test principle, clamping force 0~ 40kg/cm ² adjustable.

$ 5026.00

Adopt 5 inch high definition Touchscreen and precision ball screw drive system, Force Measurement range 0.02-100 N, Accuracy grade 0.5, support a variety of units and intelligent operation test results, with overload protection and USB data connection function.

$ 1590.00

Impact angle of 90 °, can test 5 groups of specimens at the same time, the minimum reading value is 0.005 kg-cm, the mechatronics design is compact, and meets the requirements of many international standards.

$ 3903.00

Precision ball screw drive and double rail design, Force Measurement range 0.03-200 N, Accuracy grade 0.5, support a variety of unit selection and intelligent calculation test results, equipped with micro printer and overload protection function.

$ 1590.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.