Mass stirrer

A quality stirrer drives the blades to rotate through a motor, ensuring uniform mixing of liquids or mixtures. It is used for laboratory sample preparation, chemical reactions, and material dispersion. Commonly applied in processes such as color matching and stirring of coatings and inks, as well as mixing paper pulp.
Selection
Select the appropriate power based on material viscosity; use stainless steel for corrosive substances; consider temperature-resistant designs for high-temperature environments. Determine the length of the stirring rod according to the container size; choose a stepless speed regulation model for variable speed requirements; opt for explosion-proof or sealed structures for special processes.

Terms

Standards

Instruments

Single precision mass Sensor, Response fast and durability, with 0.1mg/0.5mg Readability and six filter adjustable function, support a variety of weighing modes such as percentage, density direct reading and dynamic weighing.

$ 1824.00

Single precision mass Sensor technology, Weighing Response Fast and Stability, with 0.1mg accuracy and six filter adjustable function, supports a variety of weighing modes such as percentage and density direct reading.

$ 2287.00

Impact energy 90mJ, Impact mass 20g, can detect the maximum Hardness 650HV, Cedar depth 41-53μm, suitable for asperity 6.3μm surface.

$ 364.00

Impact energy 2.7mJ, Impact mass 3.0g, tungsten carbide ball head Hardness up to 1600HV, suitable for asperity 0.4um surface, providing accurate Hardness measurement.

$ 167.00

Using 32-bit embedded microprocessor and customized operating system, with 250 rpm vibration frequency and 3mm vibration amplitude, support automatic mass reading and built-in micro printer function.

$ 1332.00

Single precision mass Sensor technology, Weighing Response Fast and strong stability, with 0.1mg readability accuracy and six filter adjustable function, support custom internal calibrating and a variety of weighing modes to ensure accurate and reliable weighing data.

$ 3078.00

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Single precision mass Sensor technology, Response fast and durability; with 0.1mg/0.5mg High Accuracy and six filter adjustable function, support a variety of weighing modes such as percentage and dynamic weighing, adapt to complex environment.

$ 1711.00

The instrument is designed with a heavy hammer structure, with a weight mass of 6600g +/- 33g, which is suitable for the bending performance test of reflective film. It is simple to operate and safe and reliable to measure, and meets the requirements of national standards.

$ 522.00

Using stopwatch counting method, the length of the swing Rod is 500 +/- 1mm, and the total mass of the swing is 120 +/- 1g. The resistance to deformation is evaluated by measuring the ratio of the swing amplitude time on the film to the swing time on the Glass.

$ 251.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Measurement range 0.0001% to 100% with Karl Fischer Coulometry, built-in mass storage for 20,000 records, multiple calculation formulas and automatic unit conversion.

$ 1316.00

Impact test with heavy hammer free fall, impact height 50cm, drop weight mass 1000g, punch diaMeter 8mm, safe and reliable operation, easy to use in the field and laboratory.

$ 231.00

High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.

$ 157.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Rubber abrasion tester measures tire wear resistance.
The rubber abrasion tester evaluates wear resistance by simulating the friction between tires and road surfaces. It uses a grinding wheel to rub against rubber specimens under set conditions, measuring mass loss and converting it to volume loss to assess material performance.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Melt Flow Index Tester for Measuring Plastic Flowability to Control Process
A melt flow indexer evaluates the melt flow rate of plastics by measuring the extrusion mass or volume under specific temperature and load conditions.