Color Tolerance Measurement Meter

A color tolerance colorimeter measures the spectral reflectance of a sample and a standard color, calculating the distance difference between them in the color space. It is used for quickly determining the color conformity of products on the production floor and for incoming material inspection and color difference control in industries such as coatings and plastics.
Selection
When selecting, consider matching the measurement aperture to the sample size, ensure inter-instrument differences are less than 0.4 ΔE, and the instrument must have data traceability functionality. Choose a measurement mode that includes specular reflection based on the material's surface characteristics. The working environment should maintain a temperature between 15-35℃ and avoid vibrations.

Terms

Instruments

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

Equipped with peak protection and continuous load dual mode, tolerance band indicator can set upper and lower limits, Indication Error +/- 1% FS, handheld design with a variety of fixtures to achieve accurate push-pull load testing.

$ 175.00

Handheld design is compact, easy to read high accuracy, peak protection and continuous load free switching, tolerance band indicator can set the upper and lower limits, Newton kg dual unit display, maximum measurement 100N Indication Error +/- 1% FS.

$ 175.00

The handheld design is compact, the pointer reading is convenient, the peak protection and continuous load switching, the tolerance band indicator can set the upper and lower limits, the accuracy is +/- 1% FS, and the Newton kilogram dual unit display.

$ 175.00

Pointer indicator reading, accuracy of +/- 1% FS, with peak protection function and continuous load indication free switching, with tolerance band indicator for batch testing, support Newton and kilogram dual unit display.

$ 175.00

With peak protection and continuous load indication switching function, equipped with tolerance band indicator to set the upper and lower limits, accuracy of +/- 1% FS, while displaying Newton and kilogram units, handheld design for easy portability.

$ 175.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

It is convenient to use the pointer to indicate the reading, with peak protection and continuous load indication switching function. It is equipped with a tolerance belt indicator to achieve upper and lower limit setting. The Indication Error is only +/- 1% FS, and supports the simultaneous display of Newton and kilogram units.

$ 175.00

The handheld design is small in size, the pointer reading is convenient and accurate, the peak protection and continuous load are freely switched, the tolerance band indicator can set the upper and lower limits, the Newton kilogram dual unit display, the maximum Measured value is 300N, and the Indication Error is +/- 1% FS.

$ 175.00

CHNSPEC CR30 uses 45 °/0 measurement structure, supports RGB, Lab and other Color space measurement, equipped with IPS full color screen, Measurement accuracy of 0.01.

$ 186.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

16Mm large diaMeter design, suitable for streak or large area pRoduct color measurement; Repeatability Delta E * ab is less than 0.05, Measurement time is only 0.5 seconds, to ensure stable light leakage.

$ 1445.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.