Industrial Low-Humidity Oven

Industrial low-humidity ovens reduce the internal humidity through heating and dehumidification systems, enabling rapid drying or humidity sensitivity testing of samples such as coatings and plastics, thereby preventing materials from deteriorating due to moisture.
Selection
When selecting, pay attention to the humidity control range and precision to match the sample drying requirements; consider the corrosion resistance of the chamber material and heating uniformity; determine the capacity based on the sample volume, while also considering energy consumption and maintenance costs.

Terms

Standards

Instruments

Multi-wing air supply cycle is used to ensure uniform temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, to meet a variety of industrial standard testing requirements.

$ 3995.00

Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.

$ 5576.00

Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.

$ 7287.00

Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.

$ 414.00

Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, multi-wing air supply circulation to ensure uniform temperature and humidity, support LAN interface remote monitoring and data export.

$ 6383.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.

$ 5043.00

Adopt a cascade refrigeration system to achieve a low temperature of -70 ° C, equipped with a 7-inch touch screen to support 120 sets of program editing, multi-wing air supply to ensure a uniform temperature and humidity of +/- 2 ° C, with data export and remote control functions.

$ 6044.00

The 7-inch touch controller supports 120 program settings, is equipped with a multi-wing air supply system to ensure a uniform temperature and humidity of +/- 2 ° C, and has a LAN interface to realize computer remote control and data recording functions.

$ 4672.00

Adopt cascade refrigeration system, Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and 15 safety detection functions, support remote monitoring.

$ 5592.00

Using External Sensor, Humidity accuracy of +/- 0.2 ℃ and +/- 2.5% RH respectively, Humidity Response Time as fast as 15 seconds. With Bluetooth wireless setting and download, weatherproof shell, support mobile end real-time viewing and data sharing.

$ 477.00

Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 program control capacity, support automatic calculation and fault self-diagnosis function, using cascade refrigeration system to ensure stable performance.

$ 10595.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Using Japanese Panasonic Compressor and binary low temperature circuit system, temperature control accuracy of +/- 0.5 ℃, equipped with stainless steel humidifier and nickel-chromium alloy heater, support programmed test and data recording function, to meet the demanding environment simulation needs.

$ 2639.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?