Multi-wing air supply cycle is used to ensure uniform temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, to meet a variety of industrial standard testing requirements.
Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.
Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.
Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.
Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, multi-wing air supply circulation to ensure uniform temperature and humidity, support LAN interface remote monitoring and data export.
Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.
With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.
Adopt a cascade refrigeration system to achieve a low temperature of -70 ° C, equipped with a 7-inch touch screen to support 120 sets of program editing, multi-wing air supply to ensure a uniform temperature and humidity of +/- 2 ° C, with data export and remote control functions.
The 7-inch touch controller supports 120 program settings, is equipped with a multi-wing air supply system to ensure a uniform temperature and humidity of +/- 2 ° C, and has a LAN interface to realize computer remote control and data recording functions.
Adopt cascade refrigeration system, Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and 15 safety detection functions, support remote monitoring.
Using External Sensor, Humidity accuracy of +/- 0.2 ℃ and +/- 2.5% RH respectively, Humidity Response Time as fast as 15 seconds. With Bluetooth wireless setting and download, weatherproof shell, support mobile end real-time viewing and data sharing.
Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 program control capacity, support automatic calculation and fault self-diagnosis function, using cascade refrigeration system to ensure stable performance.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Using Japanese Panasonic Compressor and binary low temperature circuit system, temperature control accuracy of +/- 0.5 ℃, equipped with stainless steel humidifier and nickel-chromium alloy heater, support programmed test and data recording function, to meet the demanding environment simulation needs.