Copper Plate Magnetic Induction Thickness Gauge

The copper plate magnetic induction thickness gauge generates a magnetic field through a probe, measures the change in magnetic flux between the copper plate surface and the substrate to calculate thickness. It is used for detecting the thickness of copper layers and is commonly applied in quality control for circuit boards and metal coatings.
Selection
When selecting, consider the measurement range covering the sample thickness, precision matching requirements, probe size adapting to the measured shape, calibration method being simple, and environmental interference resistance meeting on-site conditions.

Terms

Standards

Instruments

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-3000μm, accuracy +/- 3%, automatically identify the matrix material, no need to calibrate only zero, easy to carry and lightweight.

$ 787.00

Using magnetic Induction and eddy Current dual technology, Measurement range 0-1500μm, accuracy +/- 2%, Probe wear resistance more than 500,000 times, support single point and multi-point calibrating, suitable for various environments.

$ 306.00

Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.

$ 359.00

Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.

$ 340.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.

$ 186.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Using magnetic Induction principle to achieve nondestructive measurement, with a wide range of 0~ 12000 μm and +/- 3% error accuracy, supports automatic matrix recognition and single continuous dual mode measurement, with USB and Bluetooth data output interface.

$ 622.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.

$ 180.00

Using magnetic Induction principle, Measurement range 0-3000μm, accuracy +/- 3%, integrated Probe design, minimum measurable Φ 25mm plane and convex 5mm surface, to meet a number of international standards.

$ 677.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Adopt magnetic Induction technology for measurement in the range of 0-1500 μm, error +/- 1%, equipped with 90 ° Probe for easy operation in confined spaces, with color Touchscreen and USB interface to display data in real time.

$ 1602.00

Articles

The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.
Application of Tensile Testing Machine in Coating Peel Strength Testing of Silicon-Carbon Anode Materials
This article introduces how to use a tensile testing machine to measure the bonding strength between silicon-carbon anode material coatings and copper foil substrates in lithium-ion battery research and development. During the test, the coating is peeled off using the 180-degree peel method at a constant speed, and the force variations throughout the peeling process are recorded.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.