Small-scale Polymer Coating Machine

The small-scale polymer Coater uses a motor to drive a blade or roller, evenly applying a polymer solution onto the substrate surface. It is used in laboratories to simulate coating processes, test parameters such as coating adhesion and thickness, and is suitable for experimental coating on materials like paper and film.
Selection
When selecting, consider matching the coating width with the substrate size, ensuring the coating thickness range meets experimental needs, and that the temperature control accuracy is suitable for the material properties. The operation interface should be simple and easy to maintain. Prioritize modular designs for easy functional expansion, and select materials that are chemically corrosion-resistant to ensure long service life.

Terms

Standards

Instruments

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Using open ceramic core liquid complex design, with solid polymer reference system, Measurement range 0~ 14pH, Temperature range 0~ 80 ℃, Membrane Impedance lower than 250MΩ, to ensure Stability and long life.

$ 243.00

With open liquid network design, equipped with solid polymer reference system, Measurement range 0-14pH, Temperature range 0-80 ℃, to ensure long-term Stability and anti-pollution ability.

$ 172.00

Using open liquid complex structure, equipped with solid polymer reference electrolysis solution, the membrane resistance is less than 200MΩ, suitable for -5~ 80 ℃ wide temperature environment, to ensure long-term stable measurement.

$ 243.00

Open + ceramic core liquid complex design, equipped with solid polymer reference electrolysis solution, membrane Impedance below 250MΩ, Measurement range covering 0~ 14pH, temperature adaptability 0~ 80 ℃, to ensure long-term Stability and Fast Response.

$ 243.00

It is designed with an open liquid complex combined with a ceramic core, equipped with a solid polymer reference electrolysis solution, and the membrane Impedance is less than 250MΩ. It has long life characteristics and a wide temperature range of 0-80 ° C.

$ 404.00

Adopt scale differential head adjustment, Graduation 10μm, film thickness 0~ 5000μm adjustable, accuracy +/- 2μm, Drawdown blade straightness +/- 2μm, die steel material wear and corrosion resistance.

$ 519.00

Adopt scale differential head adjustment, Graduation 10μm, Drawdown blade straightness +/- 2μm, with 0~ 5000 micron large range adjustable and die steel Drawdown blade high wear resistance and corrosion resistance.

$ 735.00

Adopt scale differential head adjustment, Graduation 10μm, film range 0~ 5000μm, accuracy +/- 5μm, Drawdown blade straightness +/- 2μm, die steel material to ensure high wear resistance and corrosion resistance.

$ 896.00

It adopts the combination design of open liquid network part and ceramic core, equipped with solid polymer reference electrolysis solution, the membrane Impedance is lower than 250MΩ, and the shell is made of titanium alloy, which is suitable for 0-80 ℃ temperature environment.

$ 554.00

Equipped with dual probes for simultaneous measurement of asperity and Coating thickness, Measurement range 3.4mm, minimum scale 1μm, support corrosion pit depth detection, in line with international standards such as ISO 2808.

$ 997.00

Measurement range 13-1000μm, accuracy +/- (3% H + 2) μm, non-destructive ultrasonic technology, resistance to solvents, acids, oils, water and dust, storage of 250 readings, support for USB connection and software updates.

$ 2855.00

Maximum range 500g, accuracy 20mg, metal beam thickened design, scale engraving is clear and not easy to abrasion, and the bottom is equipped with horizontal adjustment screws to ensure stability.

$ 127.00

Mirror stainless steel liner is easy to clean, natural convection cycle without noise, temperature control accuracy +/- 0.5 ℃, programmable multi-stage control, support temperature layer and timing function, volume 10L is suitable for small-scale experiments.

$ 390.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.