Industrial Color Measurement System

Industrial colorimeters capture spectral data of light reflected or transmitted by objects through photoelectric sensors, converting it into chromaticity values. They are used for on-site color comparison, formula adjustment, and quality monitoring in production, commonly applied for color difference detection in coatings, plastics, and textiles.
Selection
When selecting, consider matching the measurement aperture to the sample size, with portability for workshop inspections and benchtop models for the laboratory. Check the repeatability metrics and instrument-to-instrument consistency to ensure long-term stability. Compatibility with existing color standards and data management processes is also required.
Type
Measurement method
Caliber
light source
integrating sphere
Chromatic value repeability
Measurement shape
software
Special features

Terms

Instruments

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Contains 70 metal colors, color sample size 12.8cmx5.0cm, with high Gloss acrylic coatings, only one Color per page, suitable for high-end industrial pRoduct design.

$ 138.00

Contains 215 Colors, Fan-shaped design is easy to carry, color sample size 2.0x5.0cm, each page displays 5 Colors, bright type, widely used in Coating industry color comparison.

$ 96.00

Adopt 45/0 illumination light receiving system, 8mm measurement aperture, support single and average Measurement mode, Repeatability Standard Deviation ≤ E * within 0.1, can carry out color difference contrast analysis and color quality control.

$ 307.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

According to the Richter Hardness Measurement principle, it can perform High Accuracy detection on all metal materials, support a variety of Hardness standard conversion, Measurement range HLD 170-960, can store 600 sets of data, equipped with true color screen and USB interface.

$ 296.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

CHNSPEC CR30 uses 45 °/0 measurement structure, supports RGB, Lab and other Color space measurement, equipped with IPS full color screen, Measurement accuracy of 0.01.

$ 186.00

16Mm large diaMeter design, suitable for streak or large area pRoduct color measurement; Repeatability Delta E * ab is less than 0.05, Measurement time is only 0.5 seconds, to ensure stable light leakage.

$ 1445.00

Matte design system Color, including 290 commonly used Colors, 5 color samples per page 3.1x5.0cm, convenient for industry color comparison and application reference.

$ 93.00

The 3.5-inch TFT color screen display is clear, supports pH, ORP and temperature measurement, accuracy up to +/- 0.002pH, IP57 dustproof and waterproof grade, Type-C charging interface, lithium battery power supply, suitable for outdoor use.

$ 566.00

Infinity Optical inspection system and Modular function design can realize polarization and dark field observation; Coarse fretting coaxial focusing system fretting grid value of 2 μ m, guide column lifting device to adapt to different Film thickness workpiece detection needs.

$ 2252.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.