The light source box is equipped with standard light sources, simulating daylight, fluorescent light, and other lighting conditions to provide a stable and uniform illumination environment. It is used for comparing sample colors, observing color differences, and metamerism phenomena, and is applied in color quality control in industries such as printing, textiles, and coatings.
Selection
When selecting a light source box, it is essential to consider coverage of common standard light sources such as D65 and CWF, with illumination maintained between 1000 and 2000 lux. The interior of the box should feature a neutral gray background. Additionally, ensure the color rendering index (CRI) is above 90, check the lamp lifespan and calibration certificate, and verify that the viewing angle complies with the standard configuration of 45°/0° or 0°/45°.

Terms

Standards

Instruments

Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.

$ 2623.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.

$ 20729.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving system, the light transmitance haze accuracy is up to 0.01%, with A/C/D65 three light sources and vertical-lying dual-use observation mode, support USB interface data export, LED light source long life fast start.

$ 2010.00

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Single beam of light Optical inspection system, Light spectrum Bandwidth 4nm, Wavelength range 340~ 1000nm, with automatic zero and 100% function, sealing grating monochromator to improve Metering accuracy and Stability.

$ 307.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Temperature range of 0~ 50 ℃ and light intensity of 0~ 12000LX, support five-level light regulation and 99-segment program control, using PID intelligent temperature control system and pressure equilibrating refrigeration technology to ensure long-term continuous and stable operation.

$ 2612.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function, support a variety of data map processing.

$ 4914.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Optical inspection system with single beam of light, Light spectrum Bandwidth 4nm, Wavelength range 200-960nm, Support Transmittance, Absorbance and concentration direct reading Operating Mode, equipped with RS232 interface to connect external devices.

$ 670.00

With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.

$ 1845.00

Using the principle of polarized light interference, equipped with a quarter-wave plate compensation method, the measurement range of optical path difference is 0-589.44nm, and the measurement accuracy is +/- 4nm, which can realize qualitative observation and quantitative analysis at the same time.

$ 1923.00

Articles

Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Reflectometer Selection: Light Source Geometric Conditions and Contrast Ratio Testing
This article primarily discusses that when selecting a reflectometer, the geometric conditions of the light source are crucial, as they directly affect the accuracy of the measurement results.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Differences between xenon arc lamps, carbon arc lamps, and UV lamps in automotive interior and exterior light aging tests
Xenon lamps, carbon arc lamps, and UV lamps are three commonly used light sources in the photodegradation testing of automotive interiors and exteriors. Xenon lamps can simulate the full spectrum of sunlight, and by adjusting filters, they can match different environmental conditions, making them suitable for comprehensive evaluation of material aging.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.