Rotary Centrifuge

A centrifuge utilizes high-speed rotation to generate centrifugal force, causing components of different densities in a sample to separate and settle. It is used in laboratory separation operations such as pigment dispersion testing in coatings and inks, concentration analysis of paper pulp, and impurity separation in plastic particles.
Selection
Select the speed range and capacity specifications based on the sample characteristics, and consider temperature control functions to accommodate heat-sensitive materials. Pay attention to the corrosion resistance of the rotor material, ensuring compatibility with commonly used sample tube types. Verify power parameters against laboratory conditions to ensure operational stability.

Terms

Standards

Instruments

The 6-well design supports 15ml capacity Sample Handling, which is suitable for a variety of Centrifuge models and provides stable centrifugal separation results.

$ 127.00

It is designed with 24-hole 0.5ml specification, suitable for a variety of Centrifuge models, with high temperature resistance and high voltage characteristics and excellent chemical Stability.

$ 127.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

The 12-well design has a capacity of 5ml per well, uses high transparency material for easy observation of samples, has excellent chemical Stability, and is suitable for mainstream Centrifuge models to improve experimental efficiency.

$ 127.00

Double-sided horizontal mounting design can accommodate 40 5ml centrifuge tubes, suitable for standard centrifuge tube specifications, improving Sample Handling efficiency and ease of operation.

$ 149.00

44 1.5ml or 2.0ml centrifuge tubes can be installed vertically on both sides, providing efficient Sample Handling capability, adapting to a variety of centrifuge tube specifications, and improving the convenience of experimental operation and space utilization.

$ 149.00

Support 100 ℃ thermostatic treatment, compatible with 35 1.5ml centrifuge tubes, optional 4-degree electronic ice box and intelligent thermostatic module, suitable for a variety of experimental scenarios.

$ 148.00

12 10ml or 15ml centrifuge tubes can be installed vertically on both sides, providing stable fixation and efficient mixing. They are suitable for a variety of centrifuge tube specifications and enhance the convenience of experimental operation.

$ 149.00

Support high temperature treatment at 100 ° C, adapt to 20 0.5ml and 15 1.5ml centrifuge tubes, and use thermostatic metal Bath design to ensure uniform and stable temperature and improve experimental efficiency.

$ 148.00

The 54-hole design is suitable for 0.5ml centrifuge tube, with a maximum temperature tolerance of 100 ° C. A variety of thermostatic modules can be selected to achieve accurate temperature control to meet various experimental needs.

$ 148.00

Standard HX-D module, support 35 2.0ml centrifuge tubes, withstand 100 ℃ high temperature, adapt to a variety of modules to meet the needs of multi-sample thermostatic treatment.

$ 148.00

High temperature resistance of 100 ° C, suitable for 32-hole 0.2ml, 10-hole 0.5ml and 15-hole 1.5ml centrifuge tubes, optional electronic ice box or thermostatic metal Bath module for enhanced temperature control flexibility.

$ 148.00

12 50ml centrifuge tubes can be installed vertically on both sides, and the vertical installation design is adopted for efficient Sample Handling. The capacity is suitable for standard 50ml tubes.

$ 149.00

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

The double-sided horizontal mounting design can simultaneously accommodate 16 50ml centrifuge tubes, which are suitable for standard 50ml tube specifications and provide a stable and reliable sample carrying platform.

$ 149.00

Articles

The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.