Micro-volume UV-Vis SpectroPhotoMeter

The micro-volume UV spectrophotometer utilizes the absorption characteristics of substances to ultraviolet light to analyze concentration by measuring the absorbance of a sample solution at specific wavelengths. It is used to detect dye content in coatings and inks, plastic additive concentrations, among other applications, requiring only a micro-volume sample during operation.
Selection
When selecting, consider matching the sample type with the detection wavelength range, pay attention to whether the instrument's detection limit and linear range are suitable for the sample concentration, ensure the stability of the light source and the sensitivity of the detector, and verify compatibility with sample carriers such as micro cuvettes or capillary systems.

Terms

Standards

Instruments

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Light spectrum Bandwidth 4nm, stray light ≤ 0.1% T, using C-T monochromator structure to reduce interference, equipped with wide sample Chamber and automatic light source switching, support a variety of analysis function expansion.

$ 1138.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

1200L/mm UV dedicated grating and proportional double beam of light design, stray light ≤ 0.03% T, equipped with 10cm sample holder and automatic octet cell, support wavelength scanning and a variety of test modes.

$ 3623.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 1.8nm, can store 100 standard Linear dispersion and 200 data, support a variety of Cuvette and direct printouts.

$ 1300.00

Equipped with a large screen LCD graphic display, can accommodate 5-100mm Cuvette, wavelength Precision +/- 0.3nm, with automatic wavelength Adjustment, supports multiple test modes including Light spectrum scanning and kinetic testing.

$ 1397.00

Using Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can store 100 standard Linear dispersion and 200 data, supports a variety of Cuvette and direct printouts.

$ 1300.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

Adopt 1200L/mm UV special grating and imported photoelectric converter, stray light ≤ 0.03% T, Wavelength range 190~ 1100nm, with automatic correction wavelength error function, support 10cm sample holder to meet special needs.

$ 2252.00

With lame plating and scraping dual functions, coating speed 0-5m/min adjustable, equipped with UV light curing system, curing area 300 * 1000mm, support automatic tension control and deviation correction function.

$ 29120.00

Automatic correction of ABS value with one button, Light spectrum Bandwidth 4nm, Wavelength range 195-1000nm, 5-100mm Cuvette can be placed, Support Transmittance, Absorbance, concentration factor and other Operating Modes.

$ 816.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional dual beam of light design supports automatic octet cell, Wavelength range 190~ 1100nm, with professional wavelength correction function.

$ 2978.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.