Infrared imaging Detector

Infrared imaging detectors work by receiving the infrared radiation emitted from the surface of objects and converting it into temperature distribution images. They are used to detect internal defects in materials, identify overheating spots in equipment, and monitor temperature anomalies in production processes. In the industrial field, they assist in locating faults, evaluating coating uniformity, and detecting the integrity of seals.
Selection
When selecting, consider the temperature range and size of the detection target to match the instrument's resolution and temperature measurement accuracy. Pay attention to the compatibility between spatial resolution and the size of the object being measured. Choose the protection level based on the usage environment, and determine the instrument's form based on whether it will be fixed or handheld. The analysis software functionality should meet basic temperature analysis and image processing requirements.

Terms

Standards

Instruments

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.

$ 2368.00

Using infrared detection principle, range 0~ 1000ppm, resolution 1ppm, Response Time T90 ≤ 20s, built-in 3800mAh battery, support Data storage and Humidity detection, simple operation.

$ 1077.00

Pump suction sampling and infrared Sensor technology, range 0~ 2000ppm, resolution 1ppm, Response Time ≤ 20s, with IP65 Protection Rating and Dust Filter, adapt to harsh environment.

$ 507.00

Using infrared NDIR detection principle, range 0-5000ppm, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output, support remote monitoring and customization functions.

$ 848.00

Using infrared NDIR detection principle, range 0-3% Vol, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output, support remote monitoring and alarm functions.

$ 977.00

Using infrared NDIR detection principle, range 0-5000ppm, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and intelligent Sensor technology.

$ 1235.00

Using infrared NDIR detection principle, range 0~ 2% Vol, resolution up to 0.001, Response Time ≤ 30 seconds, support a variety of signal output and remote alarm, Sensor life up to 10 years.

$ 977.00

Using infrared NDIR detection principle, range 0~ 2% Vol, accuracy ≤ +/- 1% F. S, with flameproof structure and 10-year Sensor life, support a variety of signal output and remote monitoring.

$ 977.00

Using infrared NDIR detection principle, range 0-1000ppm, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output options, support remote data transmission and customized range.

$ 848.00

Using infrared NDIR detection principle, range 0-2% Vol, Response Time ≤ 30S, support 4-20mA and RS485 output, flameproof design is suitable for hazardous environments, Sensor life up to 5 years.

$ 977.00

Using infrared NDIR detection principle, range 0-1% Vol, resolution up to 0.001, Response Time ≤ 30 seconds, Sensor life up to 10 years, support a variety of signal output and remote monitoring, with High Accuracy and Stability.

$ 977.00

Using infrared NDIR detection principle, range 0-5% Vol, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote monitoring capability.

$ 332.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
Coating Distinctness of Image (DOI) Meter Evaluates Surface Imaging Clarity
The Coating Distinctness of Image (DOI) meter is an optical instrument used for quantifying the imaging clarity of coating surfaces. It analyzes the reflection of standard patterns on the coating, measuring the ratio of specular reflection to diffuse reflection to obtain an objective DOI value.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.