Cyclic Heating Bath

The circulating heating bath drives the heat-conducting medium to circulate in a closed system through a pump, evenly transferring heat to the temperature-controlled equipment. It is used for constant temperature control of laboratory equipment such as reaction vessels and viscometers, ensuring stable testing conditions.
Selection
When selecting, consider the temperature range and accuracy requirements, match the equipment's power and interface size. Pay attention to the material's corrosion resistance, and choose explosion-proof or cooling functions as needed. Compare heating rates and tank capacity, and check the safety protection devices.

Terms

Standards

Instruments

Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.

$ 344.00

The fully enclosed heating plate is designed without open flame, Heating power 3000W, heating up quickly and safely, and the studio stainless steel material has superior corrosion resistance.

$ 236.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.

$ 871.00

Heat collection heating method is adopted, the solution is heated uniformly and quickly, energy-saving and efficient. Temperature range is as wide as 300 ℃, speed range is 0-2600 rpm, durable magnetic steel and PTFE stirrer are equipped to support long-term stirring under vacuum and pressure reactions.

$ 243.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital display temperature control is accurate and reliable, suitable for thermostatic auxiliary heating.

$ 259.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

304 stainless steel one-time stretch forming liner, no water leakage; four-corner arc design to ensure temperature uniformity; temperature control accuracy of +/- 0.5 ℃, heating power 600W, to meet the long-term stable thermostatic needs.

$ 160.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

304 stainless steel one-time stretching liner without water leakage, four-corner arc design to reduce temperature control dead angle, Temperature Fluctuation +/- 0.5 ℃, hidden outlet pipe and silicone cover high temperature is not hot, heating power 400W.

$ 149.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.