Chemical Laboratory Dispersing Machine

The chemical laboratory disperser uses a high-speed rotating rotor to generate shear force, breaking up solid particles and uniformly distributing them in the liquid. It is used for the preparation of samples such as coatings and inks, achieving material refinement and mixing.
Selection
When selecting, consider the viscosity of the material to match the speed range, determine the container capacity based on the processing volume, pay attention to the corrosion resistance of the material, check the heat dissipation structure to ensure continuous operation, and choose vacuum or heating functions according to actual needs.

Terms

Instruments

Adopt closed system design, mixing capacity 5-200G, Speed range 1500-3500rpm, can achieve fast and efficient Mix & disperse, the operation process is quiet, pollution-free and bubble-free, support manual and intelligent two control modes.

$ 6851.00

The device can quickly mix ground dispersed materials in a closed system, with a speed range of 1500-3500 rpm, a mixing capacity of 5-150G, and features bubble-free and quiet operation.

$ 6205.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure Spreader uniformity and test accuracy.

$ 391.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure accurate and reliable test results.

$ 635.00

Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.

$ 244.00

Using film lamination technology, with 0.29mm paper Film thickness and surface Laminating, providing uniform film Spreader and solvent chemical resistance, easy hiding power, Opacity test.

$ 618.00

Using film lamination technology, it has excellent solvent and chemical resistance, ensuring uniform film Spreader, paper Film thickness 0.29mm, surface Laminating enhanced durability, suitable for a variety of test environments.

$ 443.00

Adopt frequency conversion motor to run quietly, electric lifting operation is convenient, maximum Rotation speed 3000rpm, lifting Travel 400mm, suitable for 0-20L capacity material handling.

$ 1219.00

Set grinding, dispersion, stirring functions in one, using electronic speed line, digital display Rotation speed, Motor Power 400W, Lift Travel 200mm, suitable for a variety of experimental needs.

$ 670.00

Adopt Rotation Rotation Rotation Noncontact Mixing & dispersing method, Rotation Rotation ratio 1:0.7, Processing capacity up to 700ml, can complete defoaming stirring in a few seconds to a few minutes, No need to clean appliances, Repeatability is high.

$ 3301.00

Using frequency conversion electromechanical, low noise and quiet operation, electric lift Travel up to 400mm, speed range 0-7500rpm, suitable for 0-20L Processing capacity.

$ 1364.00

Using film lamination treatment, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and surface Laminating to ensure Spreader uniformity and test accuracy.

$ 635.00

Brushless motor to avoid Toner contamination of samples and reduce noise. The processing capacity covers 150 ml to 6 liters, supports a variety of head Modular replacements, and the intelligent Touchscreen can set the program, timing, line speed and torque.

$ 3139.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent, ensure Spreader uniformity and with annotation section for easy recording.

$ 509.00

Processing capacity 2-5kg, Speed range 100-8000rpm, easy manual lifting operation, suitable for efficient Mixing & dispersing of different viscosity materials.

$ 403.00

Articles

When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
The impact of the disperser impeller structure on dispersion effectiveness.
This article mainly discusses how the impeller structure of a disperser affects the dispersion effectiveness. The impeller is the core component of a disperser, and its design directly influences the uniformity and stability of the final mixture.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.