Static Thermal Test Chamber

The static thermal test chamber controls the internal temperature through refrigeration and heating systems to simulate the tolerance of materials under different temperature environments. It is used to detect the physical and chemical changes of samples such as coatings and plastics at set temperatures, commonly employed in product quality verification and aging tests.
Selection
When selecting, consider that the temperature range should cover the testing requirements, the uniformity error should be less than the standard value, and the chamber volume should match the sample size. Pay attention to the compressor type to ensure long-term operation, the control system should be easy to operate, and the safety protection functions should be comprehensive.

Terms

Standards

Instruments

The static test is realized by the Three-Box structure air path switching method, with a maximum impact time of 999 hours and a cycle period of 9999 times. It is equipped with a binary refrigeration system for rapid cooling, and supports automatic cycling or manual selective impact.

$ 12139.00

The three-box structure is used to achieve static test, the temperature conversion time is ≤ 10 seconds, the temperature recovery is ≤ 5 minutes, the air passage switching mode intRoduces the temperature, and the temperature control accuracy is +/- 0.5 ℃, which is suitable for material thermal expansion and contraction testing.

$ 17275.00

The three-box structure is used to realize the test area is completely static, the temperature conversion time is ≤ 10 seconds, the Temperature range is -55 ℃~ + 150 ℃, and it has 120 sets of program capacity and real-time Linear dispersion recording function.

$ 15032.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

SUS304 stainless steel inner box and double insulation structure, equipped with 360 degree swirl/spin sample holder and precise ozone concentration control, temperature fluctuation +/- 0.5 ℃, support static dynamic tensile test, suitable for rubber durability research.

$ 5899.00

The Three-Box structure is used to distinguish the high temperature zone, the low temperature zone and the test zone, and the air passage is switched to achieve temperature impact. The maximum cycle period is 9999 times, and the Temperature range is -60~ 150 ° C. It supports automatic cycle or manual selective impact.

$ 8695.00

Using Three-Box structure air circuit switching technology, Temperature range covers -60 ° C to 150 ° C, the maximum cycle period is 9999 times, with binary refrigeration system to achieve rapid cooling, support automatic cycle and manual Impact mode.

$ 14548.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is combined with the forced air circuit switching, the temperature conversion time is less than or equal to 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the impact conditions are independently set in the high temperature and low temperature regions.

$ 19583.00

The three-box structure is used to achieve a completely static test zone, with a temperature conversion time of ≤ 10 seconds and a temperature recovery of ≤ 5 minutes. It has an Impact range of 150 ° C in the high temperature zone and -55 ° C in the low temperature zone, meeting the needs of rapid temperature change testing.

$ 24133.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.

$ 28684.00

The three-box structure is used to realize the static test sample, the strong cooling hot air circuit switching technology, the temperature conversion time is less than or equal to 10 seconds, the temperature recovery time is less than or equal to 5 minutes, and the temperature control function is independent in the high temperature zone, the low temperature zone and the test zone.

$ 15032.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.

$ 17307.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Determination of Static Surface Tension of Color Coatings Using the Platinum Plate Method with a Surface Tensiometer
This article introduces the method of measuring the static surface tension of colored paints using the platinum plate method. It explains the principle, which involves calculating the surface tension by measuring the force when the platinum plate is lifted from the liquid surface.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
Correlation Analysis between Puncture Strength and Bursting Strength of Paperboard
This article analyzes the correlation between the puncture strength and burst strength of cardboard. The two properties respectively measure the ability of cardboard to resist dynamic impact and static pressure. Although their testing principles differ, both are closely related to factors such as the fiber structure and lamination process of the cardboard.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.